Measurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon-emission computed tomography, thallium-201, and indium 111-monoclonal antimyosin Fab.
- 1 July 1987
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 76 (1) , 181-190
- https://doi.org/10.1161/01.cir.76.1.181
Abstract
Single photon-emission tomography (SPECT) and indium 111-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous injection of labeled Fab fragments with the use of a dual-head SPECT camera with medium-energy collimators. Immediately after the first tomographic scan, thallium-201 was injected into nine of 12 dogs and imaging was repeated. Estimated infarct size in grams was calculated from transaxially reconstructed, normalized, and background-corrected indium SPECT images with the use of a threshold technique for edge detection. Estimated noninfarcted myocardium in grams was calculated from obliquely reconstructed thallium SPECT images by a similar method. The animals were killed and infarct size in grams and true infarct size as a percentage of total left ventricular myocardial volume were measured by triphenyl tetrazolium chloride staining. Estimated infarct size from indium SPECT images showed an excellent correlation with true infarct size (r = .95, SEE = 4.1 g). Estimated percentage myocardium infarcted was calculated by dividing estimated infarct size from indium images by the sum of estimated infarct size plus estimated noninfarcted myocardium obtained from thallium images. Correlation between the estimated percentage of myocardium infarcted and true percentage of myocardium infarcted was excellent (r = .93, SEE = 4.4%). We conclude that dual-isotope SPECT with indium 111-monoclonal antimyosin antibodies and thallium-201 can accurately estimate infarct size and percentage myocardium infarcted.This publication has 20 references indexed in Scilit:
- Measurement of myocardial infarction fraction using single photon emission computed tomographyJournal of the American College of Cardiology, 1985
- Measurement of infarct size in acute canine myocardial infarction by single-photon emission computed tomography with technetium-99m pyrophosphateThe American Journal of Cardiology, 1984
- Determination of left ventricular mass by single-photon emission computed tomography with thallium-201The American Journal of Cardiology, 1984
- Early membrane damage during coronary reperfusion in dogs. Detection by radiolabeled anticardiac myosin (Fab')2.Journal of Clinical Investigation, 1983
- Myocardial Injury: Quantitation by Cell Sorting Initiated with Antimyosin Fluorescent SpheresScience, 1982
- Sites and Mechanisms of Localization of Technetium-99m Phosphorus Radiopharmaceuticals in Acute Myocardial Infarcts and other TissuesJournal of Clinical Investigation, 1977
- Localization of cardiac myosin-specific antibody in myocardial infarction.Journal of Clinical Investigation, 1976
- Dual radionuclide study of myocardial infarction. Relationships between myocardial uptake of potassium-43, technetium-99m stannous pyrophosphate, regional myocardial blood flow and creatine phosphokinase depletion.Circulation, 1976
- Precordial S-T segment elevation mapping: An atraumatic method for assessing alterations in the extent of myocardial ischemic injury: The effects of pharmacologic and hemodynamic interventionsThe American Journal of Cardiology, 1972
- Quantitative assessment of the extent of myocardial infarction in the conscious dog by means of analysis of serial changes in serum creatine phosphokinase activityJournal of Clinical Investigation, 1971