Three‐dimensional spiral MR imaging: Application to renal multiphase contrast‐enhanced angiography
- 31 July 2002
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (2) , 290-296
- https://doi.org/10.1002/mrm.10223
Abstract
A fast MR pulse sequence with spiral in‐plane readout and conventional 3D partition encoding was developed for multiphase contrast‐enhanced magnetic resonance angiography (CE‐MRA) of the renal vasculature. Compared to a standard multiphase 3D CE‐MRA with FLASH readout, an isotropic in‐plane spatial resolution of 1.4 × 1.4 mm2 over 2.0 × 1.4 mm2 could be achieved with a temporal resolution of 6 sec. The theoretical gain of spatial resolution by using the spiral pulse sequence and the performance in the presence of turbulent flow was evaluated in phantom measurements. Multiphase 3D CE‐MRA of the renal arteries was performed in five healthy volunteers using both techniques. A deblurring technique was used to correct the spiral raw data. Thereby, the off‐resonance frequencies were determined by minimizing the imaginary part of the data in image space. The chosen correction algorithm was able to reduce image blurring substantially in all MRA phases. The image quality of the spiral CE‐MRA pulse sequence was comparable to that of the FLASH CE‐MRA with increased spatial resolution and a 25% reduced contrast‐to‐noise ratio. Additionally, artifacts specific to spiral MRI could be observed which had no impact on the assessment of the renal arteries. Magn Reson Med 48:290–296, 2002.Keywords
This publication has 22 references indexed in Scilit:
- Abdominal Aortic AneurysmInvestigative Radiology, 1999
- Renal Arteries: Optimization of Three-dimensional Gadolinium-enhanced MR Angiography with Bolus-timing-independent Fast Multiphase Acquisition in a Single Breath HoldRadiology, 1999
- Value of Doppler ultrasound for the diagnosis of renal artery stenosis in childrenPediatric Nephrology, 1997
- Optimized gradient waveforms for spiral scanningMagnetic Resonance in Medicine, 1995
- The gridding method for image reconstruction by Fourier transformationIEEE Transactions on Medical Imaging, 1995
- Intravascular susceptibility contrast mechanisms in tissuesMagnetic Resonance in Medicine, 1994
- Susceptibility changes following bolus injectionsMagnetic Resonance in Medicine, 1993
- Fast Spiral Coronary Artery ImagingMagnetic Resonance in Medicine, 1992
- Deblurring for non‐2D fourier transform magnetic resonance imagingMagnetic Resonance in Medicine, 1992
- Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)IEEE Transactions on Medical Imaging, 1991