Magnetic resonance imaging of convection in laser-polarized xenon
- 1 March 2000
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review E
- Vol. 61 (3) , 2741-2748
- https://doi.org/10.1103/physreve.61.2741
Abstract
We demonstrate nuclear magnetic resonance (NMR) imaging of the flow and diffusion of laser-polarized xenon gas undergoing convection above evaporating laser-polarized liquid xenon. The large xenon NMR signal provided by the laser-polarization technique allows more rapid imaging than one can achieve with thermally polarized gas-liquid systems, permitting shorter time-scale events such as rapid gas flow and gas-liquid dynamics to be observed. Two-dimensional velocity-encoded imaging shows convective gas flow above the evaporating liquid xenon, and also permits the measurement of enhanced gas diffusion near regions of large velocity variation.
Keywords
This publication has 22 references indexed in Scilit:
- Probing Porous Media with Gas Diffusion NMRPhysical Review Letters, 1999
- Magnetic resonance imaging of laser polarized liquid xenonPhysical Review E, 1999
- NUCLEAR MAGNETIC RESONANCE AS A TOOL TO STUDY FLOWAnnual Review of Fluid Mechanics, 1999
- Rheo-NMR: nuclear magnetic resonance and the rheology of complex fluidsReports on Progress in Physics, 1999
- Pulsed-Field-Gradient Measurements of Time-Dependent Gas DiffusionJournal of Magnetic Resonance, 1998
- Low-Field MRI of Laser Polarized Noble GasPhysical Review Letters, 1998
- Suppression of Convection Artifacts in Stimulated-Echo Diffusion Experiments. Double-Stimulated-Echo ExperimentsJournal of Magnetic Resonance, 1997
- Spin-exchange optical pumping of noble-gas nucleiReviews of Modern Physics, 1997
- Study of shear thinning in high polymer solution using dynamic NMR microscopyMacromolecules, 1991
- Optical PumpingReviews of Modern Physics, 1972