High-performance liquid chromatographic determination of cefuroxime
- 1 January 1982
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 107 (1281) , 1451-1456
- https://doi.org/10.1039/an9820701451
Abstract
A rapid, precise and selective method is described for determining the purity of cefuroxime sodium. Cefuroxime is separated from closely related compounds by high-performance liquid chromatography at ambient temperature using a 10-cm column packed with 5-µm Spherisorb C6 and buffered aqueous acetonitrile as mobile phase. The eluate is monitored at 273 nm, orcinol is used as internal standard and the method has a coefficient of variation of 0.6%. The procedure is suitable for the analysis of freshly manufactured cefuroxime sodium and it also provides a reliable estimate of the potency of partly degraded samples from stability tests.Keywords