Segmented turboFLASH: method for breath-hold MR imaging of the liver with flexible contrast.
- 1 November 1990
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 177 (2) , 515-521
- https://doi.org/10.1148/radiology.177.2.2171014
Abstract
A method call segmental turbo-FLASH imaging allows high-resolution, multisection, short-inversion-time (TI) inversion-recovery (STIR), T1- or T2-weighted magnetic resonance (MR) studies of the liver to be completed within a breath-hold interval. The method as applied in a phantom and in 19 patients with hepatic lesions. Sequence comparisons were performed among segmented turboFLASH, single-shot turboFLASH, T1-weighted gradient-echo with ultrashort echo time, and T2-weighted spin-echo (SE) techniques. Signal from fat and liver could be nulled with the segmented turboFLASH method, with TIs of 10 and 300 msec, respectively; signal from these tissues could not be eliminated with the single-shot approach. Signal-difference-to-noise ratios and contrast for the best segmented sequencies were comparable with those of the best T2-weighted SE and T1-weighted gradient-echo techniques. It is concluded that it is feasible to obtain breath-hold images with arbitrary tissue contrast by means of segmented turboFLASH imaging. The method may prove helpful for the detection and characterization of hepatic lesions and will likely have applications to other anatomic regions such as the chest and pelvis.This publication has 10 references indexed in Scilit:
- First-pass cardiac perfusion: evaluation with ultrafast MR imaging.Radiology, 1990
- Snapshot flash mri. applications to t1, t2, and chemical‐shift imagingMagnetic Resonance in Medicine, 1990
- Dynamic MR imaging of the liver with Gd-DTPA: initial clinical resultsAmerican Journal of Roentgenology, 1989
- Inversion Recovery Snapshot FLASH MR ImagingJournal of Computer Assisted Tomography, 1989
- Hepatic neoplasia: breath-hold MR imaging.Radiology, 1989
- Liver metastases: optimization of MR imaging pulse sequences at 1.0 T.Radiology, 1988
- MR Angiography with Gradient Motion RefocusingJournal of Computer Assisted Tomography, 1988
- Rapid MR imaging with suspended respiration: clinical application in the liver.Radiology, 1986
- Detection of hepatic metastases: analysis of pulse sequence performance in MR imaging.Radiology, 1986
- Rapid Three-Dimensional MR Imaging Using the FLASH TechniqueJournal of Computer Assisted Tomography, 1986