Comparative Evaluation of Microultrafiltration Devices for Determination of Protein Binding
- 1 September 1988
- journal article
- research article
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 10 (3) , 310-315
- https://doi.org/10.1097/00007691-198803000-00013
Abstract
The free fraction of drugs was determined comparatively with new microultrafiltration devices, Molcut II (Catalogue No. SJGC type) (MLII) and (Catalogue No. PLGC type) (NML: a device derived by changing the membrane component of MLII), which were developed by Nihon Millipore Ltd., Tokyo, Japan. The results obtained with the device are compared with those of MPS-1 (MPS), which is commercially available from Amicon Co., Danvers, MA, U.S.A. Drugs tested are phenytoin, carbamazepine, valproic acid, the ophylline, phenobarbital, and gliclazide, In five of six drugs the free fraction by MLII shows lower values, although that by NML is in good agreement with MPS. The lower values of free fraction of drugs obtained with MLII may be caused by adsorption to the device. The adsorption increase is relatively correlated to increasing lipophilicity of drugs. The results suggest that physicochemical properties of each drug, especially hydrophobicity, should be taken into account, when a new device is used to examine protein binding of drugs. The NML, which is less expensive and is convenient because no special instrument is needed, is a reliable and satisfactory device for routine therapeutic free drug monitoring.This publication has 10 references indexed in Scilit:
- Determination of Free Valproic Acid Concentrations Using the Amicon Micropartition MPS-1 Ultrafiltration SystemTherapeutic Drug Monitoring, 1985
- KINETICS OF DRUG-ACTION IN DISEASE STATES .4. EFFECT OF PREGNANCY ON PHENOBARBITAL CONCENTRATIONS AT ONSET OF LOSS OF RIGHTING REFLEX IN RATS1985
- Equilibrium dialysis, ultrafiltration, and ultracentrifugation compared for determining the plasma-protein-binding characteristics of valproic acid.Clinical Chemistry, 1985
- Volume Shifts and Protein Binding Estimates using Equilibrium Dialysis: Application to Prednisolone Binding in HumansJournal of Pharmaceutical Sciences, 1983
- Disposition and metabolism of [3H]gliclazide in ratsEuropean Journal of Drug Metabolism and Pharmacokinetics, 1983
- Gas-chromatographic assay of free phenytoin in ultrafiltrates of plasma: test of a new filtration apparatus and specimen stability.Clinical Chemistry, 1981
- The "ultra-free" ultrafiltration technique compared with equilibrium dialysis for determination of unbound thiopental concentrations in serum.Clinical Chemistry, 1981
- Reversed-phase high-performance liquid chromatographic determination of gliclazide in human plasma.CHEMICAL & PHARMACEUTICAL BULLETIN, 1980
- Absorption and Excretion of Drugs. XXV. On the Mechanism of Rectal Absorption of SulfonamidesCHEMICAL & PHARMACEUTICAL BULLETIN, 1965
- PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENTJournal of Biological Chemistry, 1951