Transvenous Defibrillation Lead Systems
- 1 June 1996
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 7 (6) , 570-580
- https://doi.org/10.1111/j.1540-8167.1996.tb00564.x
Abstract
Transvenous Defibrillation. The use of the implantable cardioverter defibrillator has grown dramatically over the past 10 years. One of the major advances in defibrillation technology is the development of transvenous lead systems. Compared with traditional epicardial lead systems, transvenous defibrillation leads reduce perioperative mortality, hospitalization, and costs. Transvenous lead systems provide reliable sensing of ventricular tachyarrhythmias, although redetection of ventricular fibrillation can be prolonged, especially with integrated lead systems. Both ramp and burst adaptive pacing are equally effective for the termination of ventricular tachycardia and are successful in up to 90% of spontaneous events. Defibrillation thresholds are higher with transvenous leads than with epicardial patches. These thresholds are reduced with the use of multiple transvenous leads, subcutaneous patches, or with reversing shock polarity. However, the development of biphasic waveforms has made the largest impact on the efficacy of these lead systems, allowing dual coil transvenous systems to be effective in about 90% of patients. Defibrillation efficacy is further enhanced and implantation simplified by the incorporation of an active pulse generator located in the left pectoral region. Active pectoral pulse generators with biphasic waveforms will be the primary lead system for new implants.Keywords
This publication has 83 references indexed in Scilit:
- Sensing Failure in a Tiered Therapy Implantable Cardioverter Defibrillator: Role of Auto Adjustable GainPacing and Clinical Electrophysiology, 1995
- Safety of implantation of a cardioverter-defibrillator without general anesthesia in an electrophysiology laboratoryThe American Journal of Cardiology, 1995
- Implantation of transvenous nonthoracotomy cardioverter-defibrillator systems in patients with permanent endocardial pacemakersAmerican Heart Journal, 1995
- A prospective randomized comparison of autodecremental pacing to burst pacing in device therapy for chronic ventricular tachycardia secondary to coronary artery diseaseThe American Journal of Cardiology, 1993
- Endocardial pacing, cardioversion and defibrillation using a braided endocardial lead systemThe American Journal of Cardiology, 1993
- Effective single patch technique for cardioverter defibrillator implantation in humansAmerican Heart Journal, 1992
- Michel Mirowski and the automatic implantable defibrillatorThe American Journal of Cardiology, 1989
- Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator.Circulation, 1985
- Clinical transvenous cardioversion of recurrent life-threatening ventricular tachyarrhythmias: Low energy synchronized cardioversion of ventricular tachycardia and termination of ventricular fibrillation in patients using a catheter electrodeAmerican Heart Journal, 1982
- Feasibility and Effectiveness of Low-Energy Catheter Defibrillation in ManCirculation, 1973