Cerebral embolism after mechanical thrombolysis of a clotted hemodialysis access
Open Access
- 1 August 1999
- journal article
- case report
- Published by Elsevier in American Journal of Kidney Diseases
- Vol. 34 (2) , 341-343
- https://doi.org/10.1016/s0272-6386(99)70365-3
Abstract
No abstract availableKeywords
This publication has 12 references indexed in Scilit:
- Incidence, outcome, and risk factors of cerebrovascular events in patients undergoing maintenance hemodialysisAmerican Journal of Kidney Diseases, 1998
- Fatal paradoxic embolism during percutaneous thrombolysis of a hemodialysis graft.American Journal of Roentgenology, 1998
- Paradoxical cerebral air embolism from a hemodialysis catheterAmerican Journal of Kidney Diseases, 1997
- Occluded hemodialysis shunts: Dutch multicenter experience with the hydrolyser catheter.Radiology, 1996
- Mechanical thrombolysis for the treatment of thrombosed hemodialysis access grafts.Radiology, 1996
- Pulmonary emboli from pulse-spray and mechanical thrombolysis: evaluation with an animal dialysis-graft model.Radiology, 1996
- Pulmonary Embolism Following Hemodialysis Access Thrombolysis/ThrombectomyJournal of Vascular and Interventional Radiology, 1995
- Will iatrogenic pulmonary embolization be our pulmonary embarrassment?Radiology, 1994
- Mechanical versus pharmacomechanical thrombolysis for the treatment of thrombosed dialysis access graftsKidney International, 1994