I MPACT OF P ROMPT D EFIBRILLATION ON C ARDIAC A RREST AT A M AJOR I NTERNATIONAL A IRPORT
- 1 January 2002
- journal article
- research article
- Published by Taylor & Francis in Prehospital Emergency Care
- Vol. 6 (1) , 1-5
- https://doi.org/10.1080/10903120290938689
Abstract
Objective. To describe the impact of a rapidly deployable, automated external defibrillator (AED)-equipped first-responder service at Boston's Logan International Airport on the rate of survival to hospital discharge after cardiac arrest. Methods. A prospective observational outcome study was undertaken for cardiac arrests taking place on the airport grounds from January 1, 1995, to December 31, 1999. Patients were included if they were unresponsive, they had no palpable pulse and no spontaneous respirations, an AED was turned on, and the cardac arrest took place on airport grounds. Airport fire rescue and emergency medical services (EMS) personnel submitted resuscitation records and AED memory modules for each cardiac arrest. Each author independently reviewed all cardiac arrest reports and code summaries to ensure accuracy and data integrity. Relevant dispatch and response times were determined from airport fire rescue and EMS dispatch records. Patient outcome was determined from hospital patient records. Descriptive statistics were calculated. Results. The airport fire rescue crew responded to 53 cardiac arrests. Of those, 38 met inclusion criteria. In 36 of 38 cases (94.7%), the airport fire rescue crew was first to apply the defibrillator, and the first to deliver a shock in 28 of 32 cases (87.5%) where a shock was delivered. The median response time for the airport fire rescue crew was 2 minutes, with a mode of 1 minute. The EMS response times were 5:29 (95% CI 4:37–6:19) for basic life support crews and 8:07 (95% CI 7:17–8:57) for advanced life support crews. All patients who survived to hospital admission (n = 15) and hospital discharge (n = 8) received their first shock by the airport fire rescue crew. Eight patients (21.1%) survived to hospital discharge. In five of the eight survivors to hospital discharge, defibrillation by the airport crew alone achieved a return of spontaneous circulation. Conclusions. A rapidly deployable first-responder service permits early defibrillation minutes before arrival of EMS personnel. This rapid response positively impacts the return of spontaneous circulation and survival to hospital discharge after cardiac arrest.Keywords
This publication has 12 references indexed in Scilit:
- Use of Automated External Defibrillators by a U.S. AirlineNew England Journal of Medicine, 2000
- Outcomes of Rapid Defibrillation by Security Officers after Cardiac Arrest in CasinosNew England Journal of Medicine, 2000
- An Airline Cardiac Arrest ProgramCirculation, 1997
- Automatic External Defibrillators for Public Access Defibrillation: Recommendations for Specifying and Reporting Arrhythmia Analysis Algorithm Performance, Incorporating New Waveforms, and Enhancing SafetyCirculation, 1997
- Early defibrillation by EMTs: the Brussels experienceResuscitation, 1994
- Impact of First-Responder Defibrillation in an Urban Emergency Medical Services SystemJAMA, 1993
- Use of the automatic external defibrillator in homes of survivors of out-of-hospital ventricular fibrillationThe American Journal of Cardiology, 1989
- Cardiac arrest treated with a new automatic external defibrillator by out-of-hospital first respondersThe American Journal of Cardiology, 1986
- Factors influencing survival after out-of-hospital cardiac arrestJournal of the American College of Cardiology, 1986
- Improved neurologic recovery and survival after early defibrillation.Circulation, 1984