Capillary liquid chromatography interfaced to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using an on-line coupled piezoelectric flow-through microdispenser
- 1 March 2000
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 35 (3) , 369-377
- https://doi.org/10.1002/(sici)1096-9888(200003)35:3<369::aid-jms944>3.0.co;2-n
Abstract
A piezoelectric flow-through microdispenser interfacing capillary liquid chromatography (LC) with matrix-assisted laser desorption/ionization time-of-fight mass spectrometry (MALDI-TOF MS) was developed for the identification of biomolecules. The MALDI target plate was placed on a computer controlled high-resolution x–y stage, on to which the column effluent was deposited as discrete spots, which thereby facilitated tracing of the chromatographic separation. The entire target plate was sprayed with a homogeneous layer of α-cyano-4-cinnamic acid mixed with nitrocellulose by using an air-brush. Hence the tedious manual handling of a micropipetter applying matrix solution on top of each fraction collected spot was avoided. The pre-made target plates were stable for at least 3 weeks if kept in darkness at room temperature, which easily allowed re-analysis of dispensed sample spots. The integrated microsystem was characterized and optimized by means of fluidics, dispersion, operational stability and sensitivity parameters. The dispensing unit was developed specifically to match high-resolution capillary LC separations using a dispenser with an internal volume from inlet to the ejecting nozzle of 250 nl. Minimizing dead volumes was crucial in order to maintain the chromatographic resolution. The volume of the ejected droplets was of the order of 60 pl. Successful separations of seven immunoregulating peptides were made: ACTH 1–17, bradykinin, enkephalin, angiotensin III, angiotensin II, angiotensin I and ACTH 18–39. On-line sample dispensing on the target plate in combination with trace enrichment followed by automated MALDI-TOF MS identification is demonstrated, reaching a sensitivity of 100 amol. Copyright © 2000 John Wiley & Sons, Ltd.Keywords
This publication has 13 references indexed in Scilit:
- A novel interface for on-line coupling of liquid capillary chromatography with matrix-assisted laser desorption/ionization detectionRapid Communications in Mass Spectrometry, 1999
- Homogeneous sample preparation for automated high throughput analysis with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometryRapid Communications in Mass Spectrometry, 1999
- Identification of the Components of Simple Protein Mixtures by High-Accuracy Peptide Mass Mapping and Database SearchingAnalytical Chemistry, 1997
- Peer Reviewed: MALDI MS and Strategies for Protein AnalysisAnalytical Chemistry, 1997
- Coupling matrix-assisted laser desorption/ionization to liquid separationsMass Spectrometry Reviews, 1997
- Matrix-Assisted Laser Desorption Ionization Mass Spectrometry: Applications in Peptide and Protein CharacterizationProtein Expression and Purification, 1995
- Liquid sample introduction for matrix-assisted laser desorption ionizationAnalytical Chemistry, 1993
- Continuous-flow matrix-assisted laser desorption ionization mass spectrometryAnalytical Chemistry, 1993
- Matrix-assisted laser desorption mass spectrometry of proteins isolated by capillary zone electrophoresisAnalytical Chemistry, 1992
- Rapid, sensitive analysis of protein mixtures by mass spectrometry.Proceedings of the National Academy of Sciences, 1990