Protonation in electrospray mass spectrometry: Wrong-way-round or right-way-round?
- 1 November 2000
- journal article
- Published by American Chemical Society (ACS)
- Vol. 11 (11) , 961-966
- https://doi.org/10.1016/s1044-0305(00)00174-4
Abstract
The term “wrong-way-round ionization” has been used in studies of electrospray ionization to describe the observation of protonated or deprotonated ions when sampling strongly basic or acidic solutions (respectively) where such ions are not expected to exist in appreciable concentrations in solution. Study of the dependence of ionization of the weak base caffeine on the electrospray capillary potential reveals three distinct contributors to wrong-way-round ionization. At near-neutral pH in solutions of low ionic strength, protonation of caffeine results from the surface enrichment of electrolytically produced protons in the surface layer of the droplets from which ions are desorbed. For solutions made strongly basic with ammonia, gas-phase proton transfer from ammonium ions can create protonated caffeine. These two mechanisms have been discussed previously elsewhere. For solutions of high ionic strength at neutral or high pH, the data suggest that discharge-induced ionization is responsible for the production of protonated caffeine. This mechanism probably accounts for some of the wrong-way-round ionization reported elsewhere.Keywords
This publication has 25 references indexed in Scilit:
- Differentiating between Capillary and Counter Electrode Processes during Electrospray Ionization by Opening the Short Circuit at the CollectorAnalytical Chemistry, 1999
- ‘Wrong-way-round’ Electrospray Ionization of Amino AcidsRapid Communications in Mass Spectrometry, 1997
- Changes in bulk solution pH caused by the inherent controlled-current electrolytic process of an electrospray ion sourceInternational Journal of Mass Spectrometry and Ion Processes, 1997
- Electrospray mass spectra of protein cations formed in basic solutionsJournal of Mass Spectrometry, 1994
- Disparity between solution‐phase equilibria and charge state distributions in positive‐ion electrospray mass spectrometryJournal of Mass Spectrometry, 1994
- Ion formation from charged droplets: Roles of geometry, energy, and timeJournal of the American Society for Mass Spectrometry, 1993
- Electrospray analysis of proteins: A comparison of positive‐ion and negative‐ion mass spectra at high and low pHJournal of Mass Spectrometry, 1992
- Are the electrospray mass spectra of proteins related to their aqueous solution chemistry?Journal of the American Society for Mass Spectrometry, 1992
- Electrospray Ionization for Mass Spectrometry of Large BiomoleculesScience, 1989
- Collisional effects on the charge distribution of ions from large molecules, formed by electrospray‐ionization mass spectrometryRapid Communications in Mass Spectrometry, 1988