Accurate alignment of knee implants is essential for the success of total knee replacement. Although mechanical alignment guides have been designed to improve alignment accuracy, there are several fundamental limitations of this technology that will inhibit additional improvements. Various computer assisted techniques have been developed to examine the potential to instal knee implants more accurately and consistently than can be done with mechanical guides. For example, computer integrated instrumentation incorporates highly accurate measurement devices to locate joint centers, track surgical tools, and align prosthetic components. Image guided knee replacement provides a three-dimensional preoperative plan that guides the placement of the cutting blocks and prosthetic components. Robot assisted knee replacement allows one to machine bones accurately without the use of standard cutting blocks. The rationale for the development of computer assisted knee replacement systems is presented, the operation of several different systems is described, the advantages and disadvantages of different approaches are discussed, and areas for future research are suggested.This publication has 19 references indexed in Scilit:
- Posterior tilting of the tibial component decreases femoral rollback in posterior‐substituting knee replacement: A computer simulation studyJournal of Orthopaedic Research, 1998
- Active compliance in robotic surgery—the use of force control as a dynamic constraintProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1997
- Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplastyThe Journal of Arthroplasty, 1993
- A method for registration of 3-D shapesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1992
- Prediction of total knee motion using a three-dimensional computer-graphics modelJournal of Biomechanics, 1990
- The total condylar prosthesis. 10- to 12-year results of a cemented knee replacementThe Journal of Bone and Joint Surgery. British volume, 1989
- Patellofemoral functional results and complications with the posterior stabilized total condylar knee prosthesisThe Journal of Arthroplasty, 1988
- Posteriorly stabilised total-condylar knee replacement. Three to eight years' follow-up of 85 kneesThe Journal of Bone and Joint Surgery. British volume, 1988
- A Computational Approach to Edge DetectionPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1986
- Patellar dislocation following total knee replacement.Journal of Bone and Joint Surgery, 1985