Liquid Chromatographic Determination of Cationic Surfactants in Environmental Samples using a Continuous Post-Column Ion-Pair Extraction Detector with a Sandwich Phase Separator
- 1 November 1987
- journal article
- research article
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 31 (2-4) , 325-339
- https://doi.org/10.1080/03067318708077148
Abstract
A new detection technique is described for the quantitative analysis of cationic surfactants by HPLC via post-column ion-pair formation. A new sandwich type phase separator, as part of the extraction detector, was successfully introduced. The method was used to determine ditallowdimethylammonium chloride (DTDMAC) in various environmental samples. Detection limits of DTDMAC in river water were about 2 μg/1 (60 ng absolute; S/N = 5) and 10 ng/1 (260 pg absolute; S/N = 5), using methyl orange and 9,10-dimethoxyanthracene-2-sulphonate (DAS) as ion-pairing reagents, respectively. The environmental concentration of DTDMAC found on random samples from two Belgian rivers range from 30 to 40 μg/1. The reproducibility of the determination of DTDMAC in river water was 4.2% (RSD) (n = 20).Keywords
This publication has 17 references indexed in Scilit:
- Determination of cationic surfactants in waste- and river watersWater Research, 1984
- Automated determination of drugs in blood samples after enzymatic hydrolysis using precolumn switching and post-column reaction detectionJournal of Chromatography A, 1983
- Analytical method for a cationic fabric softener in waters and wastesJournal of Oil & Fat Industries, 1982
- Determination of trace levels of quaternary ammonium compounds in river water by liquid chromatography with conductometric detectionAnalytical Chemistry, 1982
- Automated determination of cationic surfactants by flow injection analysis based on ion-pair extractionAnalytical Chemistry, 1980
- Reversed-phase liquid chromatography of basic drugs and pesticides with a fluorigenic ion-pair extraction detectorAnalytical Chemistry, 1980
- Two-phase photometric ion-pair titrations of drugs and surfactantsAnalytical Chemistry, 1980
- Continuous post-column ion-pair extraction detection of some basic organic compounds in normal-phase chromatographyJournal of Chromatography A, 1979
- The determination of cationic surfactants in the presence of anionic surfactant in biodegradation test liquorsAnalytica Chimica Acta, 1976
- Volumetric Determination of Quaternary Ammonium Compounds and Certain Tertiary AminesJournal of the American Pharmaceutical Association (Scientific ed.), 1954