Matching between motoneurone and muscle unit properties in rat medial gastrocnemius.
- 1 April 1993
- journal article
- Published by Wiley in The Journal of Physiology
- Vol. 463 (1) , 307-324
- https://doi.org/10.1113/jphysiol.1993.sp019596
Abstract
1. Electrical and contractile (isometric) properties were studied for sixty-six motoneurone-muscle unit combinations from rat medial gastrocnemius (MG). The animals were anaesthetized with pentobarbitone. 2. The muscle units were classified into S (slow) and F (fast) on the basis of measurements of speed and fatigue resistance: the 'slow' category comprised units with an initial twitch contraction time exceeding those found among fatigue-sensitive units (border value 20 ms). 3. Twitch speed was assessed by three different measures: (i) contraction time (time to peak, range 11.4-28.0 ms), (ii) half-relaxation time (8.4-56.5 ms), and (iii) total twitch duration (34-116 ms). All three measures were mutually highly correlated and their respective values showed a continuous and unimodal distribution across the unit population. 4. The motoneurones were investigated with regard to their time course and amplitude of post-spike after-hyperpolarization (AHP; range of total durations 30-116 ms, amplitudes 0.9-8.0 mV), rheobase (0.8-17.1 nA), input resistance (0.8-5.1 M omega) and axonal conduction velocity (33-85 m/s). 5. Motoneurones of slow-twitch muscle units (type S) had, on average, a significantly slower time course of AHP, a smaller rheobase, a higher input resistance and more slowly conducting axons than those innervating fast-twitch muscle units. 6. Across the whole neuronal sample, input conductance (reciprocal of input resistance) correlated well with rheobase (r = 0.74). However, the differences in rheobase did not seem to be caused exclusively by the associated differences in input conductance. 7. Throughout the sampled population, the relative slowness of AHP showed a continuous and highly significant correlation with the relative slowness of the corresponding unit twitch. The absolute duration of AHP was close to that of the twitch. In the Discussion it is argued that this 'speed match' between motoneurone and muscle unit would help ensure that barely recruited motoneurones start firing at a frequency that is optimally suited for the subsequent rate gradation of force. 8. AHP amplitude was, on average, significantly smaller for fast-twitch than for slow-twitch motoneurones. Calculations indicated that these differences were almost completely caused by the associated differences in input resistance; the computed value for the conductance change underlying the AHP was nearly the same for fast- and slow-twitch motoneurones. 9. A simple neurone model was used to calculate the consequences of the differences in AHP amplitude and duration for repetitive discharge properties of fast and slow cell categories.(ABSTRACT TRUNCATED AT 400 WORDS)Keywords
This publication has 31 references indexed in Scilit:
- Threshold current for repetitive impulse firing in motoneurones innervating muscle fibres of different fatigue sensitivity in the catBrain Research, 1981
- Input conductance, axonal conduction velocity and cell size among hindlimb motoneurones of the catBrain Research, 1981
- Tetrapartite classification of motor units of cat tibialis posteriorJournal of Neurophysiology, 1980
- Voltage‐sensitive outward currents in cat motoneurones.The Journal of Physiology, 1980
- Physiological and histochemical characteristics of motor units in cat tibialis anterior and extensor digitorum longus musclesJournal of Neurophysiology, 1980
- Rhythmic properties of motoneurones innervating muscle fibres of different speed in m. gastrocnemius medialis of the catBrain Research, 1979
- Anatomy of medial gastrocnemius and soleus motor nuclei in cat spinal cordJournal of Neurophysiology, 1977
- Physiological types and histochemical profiles in motor units of the cat gastrocnemiusThe Journal of Physiology, 1973
- The repetitive impulse discharge of a simple neurone model compared to that of spinal motoneuronesBrain Research, 1968
- Stimulation of spinal motoneurones with intracellular electrodesThe Journal of Physiology, 1956