Optically Dilute, Absorbing, and Turbid Phantoms for Fluorescence Spectroscopy of Homogeneous and Inhomogeneous Samples
Open Access
- 1 December 1993
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 47 (12) , 2114-2121
- https://doi.org/10.1366/0003702934066244
Abstract
This paper presents a phantom which simulates the optical properties of tissue. The phantom absorption coefficient, scattering coefficient, anisotropy factor, and fluorescence quantum yield can be independently varied to investigate the effects of these parameters on fluorescence excitation and emission spectra from 300 to 650 nm. Phantom fluorophores include Flavin Adenine Dinucleotide (FAD) and Rhodamine B. Absorption is controlled by adjusting phantom hemoglobin concentration. On the basis of their smoothly varying scattering coefficient and the relatively low amount of fluorescence contributed to the mixture in comparison to other available scatterers, 1.05-µm-diameter polystyrene microspheres were selected as a scatterer. Sample inhomogeneities are simulated by preparing the phantom in a gelatin substrate. The optical properties of turbid phantoms determined with the use of indirect techniques agree well with known values as long as µs(l – g) > µa. Data are presented from dilute, absorbing, and turbid phantoms and inhomogeneous phantoms to qualitatively illustrate the effects of optical properties and sample geometry on fluorescence spectra. The phantom provides the framework for detailed quantitative investigations of the effects of optical properties, sample size, shape, and structure, boundary conditions, and collection geometry on fluorescence spectra.Keywords
This publication has 15 references indexed in Scilit:
- Gastrointestinal tissue diagnosis by laser-induced fluorescence spectroscopy at endoscopyGastrointestinal Endoscopy, 1990
- A review of the optical properties of biological tissuesIEEE Journal of Quantum Electronics, 1990
- Biochemical basis for the difference between normal and atherosclerotic arterial fluorescence.Circulation, 1989
- Time resolved reflectance and transmittance for the noninvasive measurement of tissue optical propertiesApplied Optics, 1989
- Accuracies of the diffusion approximation and its similarity relations for laser irradiated biological mediaApplied Optics, 1989
- Measurements and calculations of the energy fluence rate in a scattering and absorbing phantom at 633 nmApplied Optics, 1989
- A one-layer model of laser-induced fluorescence for diagnosis of disease in human tissue: applications to atherosclerosisIEEE Transactions on Biomedical Engineering, 1989
- Tissue optics for a slab geometry in the diffusion approximationLasers in Medical Science, 1987
- Principles of Fluorescence SpectroscopyPublished by Springer Nature ,1983
- Light intensity measurements I: Large area bolometers with microwatt sensitivities and absolute calibration of the Rhodamine B quantum counterAnalytical Chemistry, 1979