Abstract
Breakage or loosening of locking screws may impair fracture fixation or bone healing in locked nailing of tibial fractures. Bending strength and bone holding power, two important design objectives of locking screws, may conflict with each other. The present study used multiobjective optimization with a genetic algorithm to investigate the optimal designs with respect to these two objectives. Three‐dimensional finite element models for analyzing bending strength and bone holding power of locking screws were created first. Through use of a Taguchi L25orthogonal array, two objective functions were developed by least‐squares regression analyses. Then, the trade‐off solutions between the two objectives known as Pareto optima were explored by a weighted‐sum aggregating approach under geometric constraints. The objective functions, reliably reflecting the finite element results, were valid for multiobjective studies. The Pareto fronts of the screws with 4.5‐mm and 5.0‐mm outer diameters were similar. The “knee” region of the Pareto front, characterized by the fact that a small improvement in either objective will cause a large deterioration in the other objective, might be the favored choice of optimal designs. The commercially available locking screws compared with the Pareto optima were found to be dominated designs and could be improved. In conclusion, the multiobjective optimization with a genetic algorithm was useful for optimization of locking screw design with many variables and conflicting objectives. Choosing an optimal design requires a thorough knowledge of the inherent problems. This method could reduce the time, cost, and labor associated with the screw development process. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop ResKeywords
This publication has 14 references indexed in Scilit:
- Mechanical tests and finite element models for bone holding power of tibial locking screwsClinical Biomechanics, 2004
- Mechanical Strength, Fatigue Life, and Failure Analysis of Two Prototypes and Five Conventional Tibial Locking ScrewsJournal of Orthopaedic Trauma, 2002
- Multiobjective Optimization in Quantitative Structure−Activity Relationships: Deriving Accurate and Interpretable QSARsJournal of Medicinal Chemistry, 2002
- Bending Strength and Holding Power of Tibial Locking ScrewsPublished by Wolters Kluwer Health ,2001
- Cancellous Bone Screw Thread Design and Holding PowerJournal of Orthopaedic Trauma, 1996
- Factors Affecting the Pullout Strength of Cancellous Bone ScrewsJournal of Biomechanical Engineering, 1996
- The Rationales of Interlocking Nailing of the Femur, Tibia, and HumerusClinical Orthopaedics and Related Research, 1996
- Stability of Transpedicle Screwing for the Osteoporotic SpineSpine, 1993
- Biomechanical Testing of a New Design for Schanz Pedicle ScrewsJournal of Orthopaedic Trauma, 1993
- Optimizing Bone Screw Pullout ForceJournal of Orthopaedic Trauma, 1990