Polymeric reagents for derivatizations in micellar electrokinetic chromatography
- 1 September 1994
- journal article
- Published by Wiley in Biomedical Chromatography
- Vol. 8 (5) , 212-218
- https://doi.org/10.1002/bmc.1130080504
Abstract
A polymer immobilized o‐nitrobenzophenone reagent was prepared for analysis of amine drugs in micellar electrokinetic chromatography (MEKC). A model compound, propylamine, was used to characterize the reagent's performance in MEKC. Derivatizations were performed on the CE instrument with reagent in the sample vial. The yielded derivative was directly sampled from the reaction mixture, and directly injected onto the MEKC system. The derivatization reagent was also applied to the derivatization of n‐alkyl amine mixtures and amino acids. The method was validated for adamantanamine in urine and amino acids. The method was validated for adamantanamine in urine and in plasma by single‐blind spike analysis. Precisions and accuracies for all samples were less than 6.0% for urine samples and 10% for plasma samples. The procedure was a direct injection technique requiring minimal sample preparation for the analysis of drugs in biofluids.Keywords
This publication has 21 references indexed in Scilit:
- On-Column Sample Concentration Using Field Amplification in CZEAnalytical Chemistry, 1992
- The Use of a Concentration Step to Collect Urinary Components Separated by Capillary Electrophoresis and Further Characterization of Collected Analytes by Mass SpectrometryJournal of Liquid Chromatography, 1991
- Fluorescence detection in capillary electrophoresis: evaluation of derivatizing reagents and techniquesAnalytical Chemistry, 1991
- Solid-phase reagent containing the 3,5-dinitrophenyl tag for the improved derivatization of chiral and achiral amines, amino alcohols and amino acids in high-performance liquid chromatography with ultraviolet detectionJournal of Chromatography A, 1991
- A mixed-bed, multi-derivatization approach using polymeric reagents for derivatizations of amines in high performance liquid chromatographic detectionBiomedical Chromatography, 1991
- On-line isotachophoretic sample preconcentration for enhancement of zone detectability in capillary zone electrophoresisJournal of Microcolumn Separations, 1990
- Interaction of capillary zone electrophoresis with a sheath flow cuvette detectorAnalytical Chemistry, 1990
- Chiral polymeric reagents for off-line and on-line derivatizations of enantiomers in high-performance liquid chromatography with ultraviolet and fluorescence detection: an enantiomer recognition approachAnalytical Chemistry, 1989
- Internal surface reversed-phase silica supports for liquid chromatographyAnalytical Chemistry, 1985
- Active esters of polymer-bound 4-hydroxy-3-nitrobenzophenone as useful acylating reagents. Application to peptide synthesisThe Journal of Organic Chemistry, 1984