Abstract
For stability studies of large power systems, accurate representation of the synchronous machine is required. As pointed out by Canayl, the conventional equivalent circuits for synchronous machines do not give accurate computed field voltage and current values. He suggested several circuits and showed good agreement between his test and calculated results. His circuit parameters were calculated from design.Keywords
This publication has 3 references indexed in Scilit:
- Causes of Discrepancies on Calculation of Rotor Quantities and Exact Equivalent Diagrams of the Synchronous MachineIEEE Transactions on Power Apparatus and Systems, 1969
- New Measurement of Synchronous Machine QuantitiesIEEE Transactions on Power Apparatus and Systems, 1968
- Per-Unit Impedances of Synchronous MachinesTransactions of the American Institute of Electrical Engineers, 1945