Field Displacement During External Radiotherapy In Prostatic Adenocarcinoma Treated With Radioactive 198Au Implants And External Irradiation
- 1 January 1995
- journal article
- research article
- Published by Taylor & Francis in Acta Oncologica
- Vol. 34 (7) , 959-964
- https://doi.org/10.3109/02841869509127212
Abstract
The purpose of this work was to study displacement error and internal movements of the prostate during external beam radiotherapy. Verification films in the frontal (n = 194) and lateral (n = 64) portals were investigated in 14 patients treated with radioactive 198Au implants. Displacement errors of two implants were investigated. In seven patients, filling of the rectum and the bladder with contrast medium or isotonic saline was performed during CT investigation for planning purposes to detect movements of the prostate. Most (95%) of the displacement errors were less than 10 mm in the frontal portal and less than 15 mm in the lateral portals. No correlation to the patient's weight was found. The displacement errors were randomly distributed. The spatial relations between the implants were not altered during the treatments. Small movements of the prostate were observed. To conclude, the positioning system employed at present (laser) can be sufficient for the margins used (2 cm). In lateral portals, however, the system did not have the ability to detect a possible systematic displacement error from simulator to accelerator. The intention is to decrease the margins to 1 cm, which will necessitate a better positioning system.Keywords
This publication has 19 references indexed in Scilit:
- A randomised trial of patient repositioning during radiotherapy using a megavoltage imaging systemRadiotherapy and Oncology, 1994
- On-line portal imaging: Image quality defining parameters for pelvic fields—a clinical evaluationInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Immobilization improves the reproducibility of patient positioning during six-field conformal radiation therapy for prostate carcinomaInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Interactive use of on-line portal imaging in pelvic radiationInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Quality control of radiotherapy during pelvic irradiationRadiotherapy and Oncology, 1991
- Conformal static field therapy for low volume low grade prostate cancer with rigid immobilizationInternational Journal of Radiation Oncology*Biology*Physics, 1991
- Reproducibility of Field Alignment in Radiation therapy: A Large-Scale Clinical ExperienceActa Oncologica, 1989
- Accuracy of radiation field alignment in clinical practiceInternational Journal of Radiation Oncology*Biology*Physics, 1985
- Weekly localization films and detection of field placement errorsInternational Journal of Radiation Oncology*Biology*Physics, 1978
- Errors in reproducing pelvic radiation portalsInternational Journal of Radiation Oncology*Biology*Physics, 1977