Single motor unit analysis from spatially filtered surface electromyogram signals. Part I: Spatial selectivity
- 1 May 2003
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 41 (3) , 330-337
- https://doi.org/10.1007/bf02348439
Abstract
The aim of the study was to compare experimentally, on the basis of single motor unit (MU) activities, the selectivity of different spatial filters commonly used to detect surface electromyogram (EMG) signals. Surface EMG signals were recorded from the biceps brachii and the upper trapezius muscle of five subjects using a two-dimensional (2D) electrode array consisting of 16 pin electrodes. The subjects performed isometric contractions at different elbow angles and shoulder abduction and flexion. The same monopolar surface EMG signals were filtered using longitudinal single and double differential, transverse single and double differential and normal double differential filters. From the single MU action potentials, extracted by automatic EMG decomposition, indexes of transverse (perpendicular with respect to the fibre direction) and longitudinal (along the fibre direction) selectivity were computed. The number of detected MUs was 48 for the upper trapezius, with the arms held in the sagittal plane, and 52 when the arms were held in the frontal plane; 85 MUs were identified from the biceps brachii contractions. The results showed that transverse selectivity was significantly higher for the 2D and transverse onedimensional (1D) filters with respect to the 1D longitudinal filters, whereas longitudinal selectivity was higher (i.e. MU action potentials were shorter) for the 2D filter and the longitudinal double differential filter. In particular, the relative attenuation of potential amplitude moving 5 mm from the source was, on average (for the two muscles), 16.5% for the least selective filter in the transverse direction (longitudinal single differential) and 35.7% for the most selective one in the same direction (transverse double differential). The MU action potential duration was, on average, 13.8 ms for the most selective filter in the longitudinal direction (longitudinal double differential) and 18.7 ms for the least selective one (transverse double differential). The normal double differential filter resulted in spatial selectivity indexes that were not statistically different in the two directions from those of the best filters in each direction.Keywords
This publication has 25 references indexed in Scilit:
- Surface EMG crosstalk between knee extensor muscles: Experimental and model resultsMuscle & Nerve, 2002
- Influence of anatomical, physical, and detection-system parameters on surface EMGBiological Cybernetics, 2002
- Standardising surface electromyogram recordings for assessment of activity and fatigue in the human upper trapezius muscleEuropean Journal of Applied Physiology, 2002
- Concentric-ring electrode systems for noninvasive detection of single motor unit activityIEEE Transactions on Biomedical Engineering, 2001
- Non-invasive approach of motor unit recording during muscle contractions in humansEuropean Journal of Applied Physiology, 2000
- The motor unit potential distribution over the skin surface and its use in estimating the motor unit locationActa Physiologica Scandinavica, 1997
- Improvement of spatial resolution in surface-EMG: a theoretical and experimental comparison of different spatial filtersIEEE Transactions on Biomedical Engineering, 1997
- Clinical Application of a Noninvasive Multi-Electrode Array EMG for the Recording of Single Motor Unit ActivityNeuropediatrics, 1993
- Far‐field potentials in muscleMuscle & Nerve, 1991
- A surface electrode array for detecting action potential trains of single motor unitsElectroencephalography and Clinical Neurophysiology, 1985