Transpedicular screw fixation
- 1 January 1989
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 7 (1) , 107-114
- https://doi.org/10.1002/jor.1100070115
Abstract
Spinal fixation employing transpedicular screws has recently been the focus of increased attention at various institutions throughout the world, but concerns about the safety and efficacy of transpedicular screws linger. This study was undertaken to address some of these concerns. The study included evaluation of the internal and external morphology of the vertebral pedicles, which revealed that adequate bone stock is generally available at T2, T7, T12, and L1–L5 spinal levels to accept screws in the 4–7-mm diameter range. The pedicle was observed to be composed of abundant cancellous bone internally with relatively thick cortical walls. The method of pilot hole preparation for pedicle screws was also examined. Screws inserted in pilot holes prepared with a 3.4-mm blunt probe (ganglion knife) resulted in higher pullout forces in eight of 10 trials as compared with those with pilot holes prepared using a 3.2-mm drill. Furthermore, the probes afford greater control of hole depth and alignment. Fatigue studies on three screws designs revealed a graduation of strength between a 7.0-mm pedicle screw, and a modified 6.5-mm cancellous lag screw. The modified cancellous lag screw has an inherent stress riser that affected fatigue life. It was noted that extreme care must be exercised to prevent bending of the pedicle screws during implantation. If bending ocurs one can expect a 50% reduction in the number of cycles to failure.Keywords
This publication has 15 references indexed in Scilit:
- A Morphometric Study of Human Lumbar and Selected Thoracic VertebraeSpine, 1987
- Segmental Spine Plates with Pedicle Screw Fixation A New Internal Fixation Device for Disorders of the Lumbar and Thoracolumbar SpinePublished by Wolters Kluwer Health ,1986
- Total Vertebral Body and Pedicle ArthroplastyPublished by Wolters Kluwer Health ,1986
- A Biomechanical Study of Intrapeduncular Screw Fixation in the Lumbosacral SpineClinical Orthopaedics and Related Research, 1986
- Complications following Harrington instrumentation for fractures of the thoracolumbar spine.Journal of Bone and Joint Surgery, 1985
- The Treatment of Spinal Fractures with Harrington Compression Rods and Segmental Sublaminar Wiring A Dangerous CombinationSpine, 1984
- Postoperative neurological deficits in segmental spinal instrumentation. A study using spinal cord monitoring.Journal of Bone and Joint Surgery, 1984
- Late complications due to wire breakage in segmental spinal instrumentation. Report of two cases.Journal of Bone and Joint Surgery, 1983
- Clinical review of patients with broken Harrington rods.Journal of Bone and Joint Surgery, 1980
- Transarticular (transpedicular) metal plate fixation for stabilization of the lumbar and thoracic spineActa Neurochirurgica, 1979