An isotope clearance method for measurement of liver blood flow during portasystemic shunt in man
- 1 August 1978
- journal article
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 65 (8) , 578-580
- https://doi.org/10.1002/bjs.1800650815
Abstract
The clearance from the surface of the liver of krypton 85 following its injection into the portal vein was measured in 10 patients. Six control patients (i.e. those not suffering from portal hypertension) averaged flow values of 142 ml per 100 g liver weight per min. A repeat flow estimation in these patients was not significantly different. Four patients with portal hypertension were studied. In 2 with congenital hepatic fibrosis the portal vein was temporarily occluded to allow prediction of the degree of hepatic perfusion likely to be achieved by the hepatic artery alone after portal deviation. The flow after portal venous clamping was unaffected in one of these cases but reduced by 45 per cent in the other. In a patient undergoing a Warren distal splenorenal shunt there was no change in flow after the procedure. If measurements are performed before and during temporary portal vein occlusion, an assessment of the flow reduction to be expected after a shunt procedure can be made. We suggest that a knowledge of liver tissue perfusion might influence the choice of operative procedure.Keywords
This publication has 10 references indexed in Scilit:
- The hepatic arterial and portal venous circulations of the liver studied with a krypton-85 clearance techniqueJournal of Surgical Research, 1978
- Measurement of liver blood flow in the dog using krypton-85 clearance: A comparison with electromagnetic flowmeter measurementsJournal of Surgical Research, 1978
- Hepatic Artery Flow Improvement After Portacaval ShuntAnnals of Surgery, 1976
- Use of Hemodynamic Selection Criteria in the Management of Cirrhotic Patients with Portal HypertensionAnnals of Surgery, 1974
- Measurement of dual hepatic blood flow in awake patients.Journal of Applied Physiology, 1973
- Intrahepatic distribution of portal and hepatic arterial blood flows in anaesthetized cats and dogs and the effects of portal occlusion, raised venous pressure and histamineThe Journal of Physiology, 1972
- Determination of the Hepatic Blood Flow in Man by Simultaneous Use of Five Test Substances Measured in Two Parts of the LiverScandinavian Journal of Clinical and Laboratory Investigation, 1965
- The Importance of Hemodynamic Studies in Management of Portal Hypertension*Annals of Surgery, 1963
- NEUROPSYCHIATRIC COMPLICATIONS OF PORTACAVAL ANASTOMOSISThe Lancet, 1961