Inactivation of Viruses in Bubbling Processes Utilized for Personal Bioaerosol Monitoring
Open Access
- 1 December 2004
- journal article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 70 (12) , 6963-6967
- https://doi.org/10.1128/aem.70.12.6963-6967.2004
Abstract
A new personal bioaerosol sampler has recently been developed and evaluated for sampling of viable airborne bacteria and fungi under controlled laboratory conditions and in the field. The operational principle of the device is based on the passage of air through porous medium immersed in liquid. This process leads to the formation of bubbles within the filter as the carrier gas passes through and thus provides effective mechanisms for aerosol removal. As demonstrated in previous studies, the culturability of sampled bacterium and fungi remained high for the entire 8-h sampling period. The present study is the first step of the evaluation of the new sampler for monitoring of viable airborne viruses. It focuses on the investigation of the inactivation rate of viruses in the bubbling process during 4 h of continuous operation. Four microbes were used in this study, influenza, measles, mumps, and vaccinia viruses. It was found that the use of distilled water as the collection fluid was associated with a relatively high decay rate. A significant improvement was achieved by utilizing virus maintenance fluid prepared by using Hank's solution with appropriate additives. The survival rates of the influenza, measles, and mumps viruses were increased by 1.4 log, 0.83 log, and 0.82 log, respectively, after the first hour of operation compared to bubbling through the sterile water. The same trend was observed throughout the entire 4-h experiment. There was no significant difference observed only for the robust vaccinia virus.Keywords
This publication has 14 references indexed in Scilit:
- Development and evaluation of a new personal sampler for culturable airborne microorganismsAtmospheric Environment, 2002
- Methods for Integrated Air Sampling and DNA Analysis for Detection of Airborne Fungal SporesApplied and Environmental Microbiology, 2001
- Survival of Airborne Microorganisms During Swirling Aerosol CollectionAerosol Science and Technology, 2000
- Long-term sampling of airborne bacteria and fungi into a non-evaporating liquidAtmospheric Environment, 1999
- Removal of Aerosols by Bubbling Through Porous MediaAerosol Science and Technology, 1999
- Improved Aerosol Collection by Combined Impaction and Centrifugal MotionAerosol Science and Technology, 1998
- EVALUATION OF EIGHT BIOAEROSOL SAMPLERS CHALLENGED WITH AEROSOLS OF FREE BACTERIAAihaj Journal, 1992
- Collection efficiency of liquid samplers for microbiological aerosolsJournal of Aerosol Science, 1988
- Sampling and analysis of biological aerosolsAtmospheric Environment (1967), 1987
- Failure to cleave measles virus fusion protein in lymphoid cells. A possible mechanism for viral persistence in lymphocytesThe Journal of Experimental Medicine, 1981