Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x‐ray imaging
- 1 October 1997
- journal article
- Published by Wiley in Medical Physics
- Vol. 24 (10) , 1643-1646
- https://doi.org/10.1118/1.597973
Abstract
Skin entrance doses of patients undergoing interventional x‐ray procedures are capable of causing skin damage and should be monitored routinely. Single TLD chips are not suitable because the location of maximum skin exposure cannot be predicted. Most photographic films are too sensitive at diagnostic x‐ray energies for dosimetry, exhibit temporal changes in response, and require special packaging by the user. We have investigated the suitability of laser heated TLDs in a polyimide binder in the range of 0.2–20 Gy. These are available in radioluscent arrays up to 30×30 cm for direct measurement of patient skin dose. Dose response was compared with a calibrated ion chamber dosimeter. Exposures were made at 60, 90, and 120 kVp, at low (fluoroscopy) and high (DSA) dose rates, and at different beam incidence angles. Longitudinal reproducibility and response to temperature changes during exposure were also checked. The dose response is linear below approximately 6 Gy where the slope starts to increase 2% per Gy. Errors were less than ±2% over a 0–80 degree range of beam incidence angles; less than ±3% for both dose rate variations and kVp differences between 70 and 120 kVp. The response was unaffected by temperature changes between 20 and 37 °C. Reproducibility is currently ±7%. TLD arrays are suitable for patient dosimetry in high dose fluoroscopy procedures if appropriate calibrations are used. Uncertainty in skin dose measurement is less than 10%, which is substantially better than film dosimetry.Keywords
This publication has 12 references indexed in Scilit:
- Evaluation of an on-line patient exposure meter in neuroradiology.Radiology, 1997
- A Survey of Films for Use as Dosimeters in Interventional RadiologyHealth Physics, 1995
- Potential Biological Effects Following High X-ray Dose Interventional ProceduresJournal of Vascular and Interventional Radiology, 1994
- Tissue doses in the upper gastrointestinal fluoroscopy examination.Radiology, 1991
- Radiotherapy Verification Film for Estimating Cumulative Entrance Skin Exposure for Fluoroscopic ExaminationsHealth Physics, 1990
- An evaluation of the Diamentor transmission ionisation chamber in indicating exposure-area product (R cm2) during diagnostic radiological examinationsPhysics in Medicine & Biology, 1982
- Exposure pattern, surface, bone marrow integral and gonadal dose from fluoroscopyThe British Journal of Radiology, 1972
- Estimation of Exposure Pattern and Bone Marrow and Gonadal Doses during FluoroscopyThe British Journal of Radiology, 1967
- A Method for Estimating the Average Bone-Marrow Dose from Some Fluoroscopic ExaminationsRadiology, 1964
- A Photographic Method of Measuring Fluoroscopic Dose to the PatientRadiology, 1961