Recent advances in endovascular devices have been aimed at providing high density, mesh-like metallic materials across the aneurysm neck, in place of coil technology. Therefore our aim was to report the in vivo preclinical performance of a self-expanding intrasaccular embolization device. Elastase-induced aneurysms were created in 12 rabbits. Each aneurysm was embolized with a Luna AES. DSA was performed preimplantation; 5, 10, and 30 minutes postimplantation; and at 1 month in 12 rabbits and at 3 months in 8 rabbits. Early postimplantation intra-aneurysmal flow was graded as unchanged, moderately diminished, or completely absent. One- and 3-month DSAs were graded by using a 3-point scale (complete, near-complete, or incomplete occlusion). Aneurysms were harvested for gross and microscopic histologic evaluation at 1 month (n = 4) and at 3 months (n = 8). Tissues within the aneurysm dome and across the aneurysm neck were assessed by using HE staining. Ten (83%) of 12 aneurysms demonstrated complete cessation of flow within 30 minutes of device implantation. At 1-month follow-up, 10 (83%) of 12 aneurysms were completely occluded. At 3 months, 7 of 8 (88%) aneurysms remained completely occluded. One-month gross examination in 4 rabbits demonstrated that membranous tissue completely covered the device in 3 subjects (75%). Microscopic examination showed that 3 aneurysms had loose connective tissue filling the aneurysm cavity. Three-month gross and microscopic examinations demonstrated membranous tissue completely covering the device, loose connective tissue filling the aneurysm cavity, and neointima formation crossing the aneurysm neck in 8 of 8 (100.0%) subjects. The Luna AES achieved high rates of complete angiographic occlusion and showed promising histologic findings in the rabbit aneurysm model.Keywords
This publication has 13 references indexed in Scilit:
- A Second-Generation, Endoluminal, Flow-Disrupting Device for Treatment of Saccular AneurysmsAmerican Journal of Neuroradiology, 2009
- The Asymmetric Vascular StentStroke, 2009
- Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent deviceNeuroradiology, 2007
- A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular AneurysmsStroke, 2007
- International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusionThe Lancet, 2005
- Endovascular coil embolization of intracranial aneurysms: important factors related to rates and outcomes of incomplete occlusionJournal of Neurosurgery, 2005
- Long-Term Angiographic Recurrences After Selective Endovascular Treatment of Aneurysms With Detachable CoilsStroke, 2003
- International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trialThe Lancet, 2002
- Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil systemJournal of Neurosurgery, 2000
- Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleedingJournal of Neurosurgery, 1999