Simple analysis of amoxycillin in plasma by high performance liquid chromatography with internal standardization and ultraviolet detection
- 1 July 1993
- journal article
- Published by Wiley in Biomedical Chromatography
- Vol. 7 (4) , 204-207
- https://doi.org/10.1002/bmc.1130070407
Abstract
A simple high performance liquid chromatographic method with ultraviolet detection at 229 nm is described for quantitation of amoxycillin in plasma. After deproteination of plasma samples with perchloric acid and adjustment of the pH to 4.9, the supernatant was injected onto a reversed phase C18 column, using acetonitrile: phosphate buffer (0.01 M, pH 7.4) (1:25 v/v) as the mobile phase. Amoxycillin and the internal standard, cefadroxil, were eluted at 23 min and 12 min, respectively, without interference from endogenous substances. Processed samples were stable for at least 24 h at room temperature which permitted automated batch processing overnight. Calibration plots of the amoxycillin to cefadroxil peak‐height ratio vs. amoxycillin concentration were linear (P < 0.0001; r⩾0.995) from 0.25 mg/L to at least 16.0 mg/L. Between‐day and within‐day imprecision (CV) ranged between 3.7% and 17.7%. Absolute recovery for amoxycillin and cefadroxil exceeded 82%. The application was demonstrated by the analysis of amoxycillin in human plasma after a single orall dose of amoxycillin (250 mg) suspension.Keywords
This publication has 14 references indexed in Scilit:
- Liquid chromatographic determination of amoxicillin concentrations in bovine plasma by using a tandem solid-phase extraction methodAntimicrobial Agents and Chemotherapy, 1992
- High Performance Liquid Chromatographic Analysis of Amoxicillin in Microliter Volumes of Chinchilla Middle Ear Effusion and PlasmaJournal of Liquid Chromatography, 1990
- Determination of amoxicillin in plasma by high-performance liquid chromatography with fluorescence detection after on-line oxidationJournal of Chromatography A, 1990
- Determination of amoxycillin in plasma by ion pair column extraction and reversed-phase ion pair high-performance liquid chromatographyJournal of Pharmaceutical and Biomedical Analysis, 1985
- High-performance liquid chromatographic assay of ampicillin, amoxicillin and ciclacillin in serum and urine using a pre-column reaction with 1,2,4-triazole and mercury(II) chlorideThe Analyst, 1985
- Assay of amoxicillin and clavulanic acid, the components of Augmentin, in biological fluids with high-performance liquid chromatographyAntimicrobial Agents and Chemotherapy, 1982
- Determination of amoxicillin in body fluids by reversed-phase liquid chromatography coupled with a post-column derivatization procedureJournal of Chromatography B: Biomedical Sciences and Applications, 1979
- Rapid determination of amoxycillin (Clamoxyl®) and ampicillin (Penbritin®) in body fluids of many by means of high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1978
- A simple chemical method for the assay of amoxycillin in serum and urineClinica Chimica Acta; International Journal of Clinical Chemistry, 1976
- AmoxycillinDrugs, 1975