A Study of Asymmetrical Gating for Phase-Controlled Converters
- 1 May 1972
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. IA-8 (3) , 289-295
- https://doi.org/10.1109/tia.1972.349759
Abstract
The low power factor of phase-controlled converters when the output voltage is less than the maximum is of-concern in high-power equipment. In a converter consisting of two commutating groups in cascade, the usually low power factor can be improved by firing or gating the thyristors in the two groups asymmetrically. One of the groups is fully advanced (or retarded) to minimize its reactive power, while the other group is controlled to give the desired dc Output. The technique is not recommended for single three-phase bridge converters because of third-hannonic output ripple, second-harmonic line current distortion, and danger of commutation failure. These objections are overcome by combining pairs of three-phase bridges. When regeneration is not required, half of the thyristors can be replaced by diodes, reducing the cost. The method should offer substantial improvement in the power factor of cycloconverter ac motor drives as well as dc motor drives.Keywords
This publication has 5 references indexed in Scilit:
- Bridge rectifiers with double and multiple supplyProceedings of the Institution of Electrical Engineers, 1969
- Semiconverter Rectifiers Go High PowerIEEE Transactions on Industry and General Applications, 1968
- Alternative convertor for h.v. d.c. transmission. Three single-phase bridges connected in seriesProceedings of the Institution of Electrical Engineers, 1968
- Das Steuerverhalten unsymmetrisch gesteuerter Stromrichter und ihr BlindleistungsbedarfElectrical Engineering, 1958
- Die Blindleistung beim dreiphasigen Stromrichter mit unsymmetrischer SteuerungElectrical Engineering, 1956