Issues and Implications in the Selection of Blood Glucose Monitoring Technologies
- 1 March 1999
- journal article
- review article
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 1 (1) , 3-11
- https://doi.org/10.1089/152091599317512
Abstract
Over the last 2 decades assay technology originating in the laboratory has been adapted for the special situation of in vitro blood glucose monitoring in the home, at work or play, or at the bedside. The availability of blood glucose monitoring devices has had a significant impact on the treatment of diabetes, especially with respect to involving the patients in their treatment. The unique requirements of this type of testing have led to novel developments in sample acquisition techniques, analyte detection, measurement techniques, and error detection. The performance of these in vitro devices in terms of accuracy and imprecision is largely dependent on factors that contribute to variation in response that are related to testing with blood samples outside of the laboratory. These factors include, for example, variations in environmental conditions, the variability of hematocrit and oxygen concentrations of the blood, and the fact that the blood is used undiluted. Therefore, the technologies used have been selected, developed, optimized, and calibrated to minimize the impact of these factors. The technologies also must be capable of providing accurate, reproducible results over the large range of clinical interest from the hypoglycemic range to glucose concentrations 10 to 15 to 20 times greater. However, when selecting a technology there are invariably some tradeoffs to consider. Thus, the products must be optimized to balance performance, reliability, and cost. Examples are discussed.Keywords
This publication has 16 references indexed in Scilit:
- Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)The Lancet, 1998
- Noninvasive Blood Glucose MonitoringDiabetes Care, 1997
- Use of a Subcutaneous Glucose Sensor To Detect Decreases in Glucose Concentration Prior to Observation in BloodAnalytical Chemistry, 1996
- Design, Characterization, and One-Point in vivo Calibration of a Subcutaneously Implanted Glucose ElectrodeAnalytical Chemistry, 1994
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- High current density "wired" quinoprotein glucose dehydrogenase electrodeAnalytical Chemistry, 1993
- Laboratory Evaluation of New Reusable Blood Glucose SensorDiabetes Care, 1988
- Quinoprotein glucose dehydrogenase and its application in an amperometric glucose sensorBiosensors, 1986
- Ferrocene-mediated enzyme electrode for amperometric determination of glucoseAnalytical Chemistry, 1984
- Electrochemical measurement of glucose using various electron acceptorsClinica Chimica Acta; International Journal of Clinical Chemistry, 1974