Experimental and numerical investigation of the 3D SPECT photon detection kernel for non-uniform attenuating media
- 1 July 1996
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 41 (7) , 1167-1189
- https://doi.org/10.1088/0031-9155/41/7/007
Abstract
Experimental tests for non-uniform attenuating media are performed to validate theoretical expressions for the photon detection kernel, obtained from a recently proposed analytical theory of photon propagation and detection for SPECT. The theoretical multi-dimensional integral expressions for the photon detection kernel, which are computed numerically, describe the probability that a photon emitted from a given source voxel will trigger detection of a photon at a particular projection pixel. The experiments were performed using a cylindrical water-filled phantom with large cylindrical air-filled inserts to simulate inhomogeneity of the medium. A point-like, a short thin cylindrical and a large cylindrical radiation source of 99Tcm were placed at various positions within the phantom. The values numerically calculated from the theoretical kernel expression are in very good agreement with the experimentally measured data. The significance of Compton-scattered photons in planar image formation is discussed and highlighted by these results. Using both experimental measurements and the calculated values obtained from the theory, the kernel's size is investigated. This is done by determining the square N x N pixel neighbourhood of the gamma camera that must be connected to a particular radiation source voxel to account for a specific fraction of all counts recorded at all camera pixels. It is shown that the kernel's size is primarily dependent upon the source position and the properties of the attenuating medium through Compton scattering events, with 3D depth-dependent collimator resolution playing an important but secondary role, at least for imaging situations involving parallel hole collimation. By considering small point-like sources within a non-uniform elliptical phantom, approximating the human thorax, it is demonstrated that on average a 12 cm x 12 cm area of the camera plane is required to collect 85% of the total count recorded. This is a significantly larger connectivity than the 3 cm x 3 cm area required if scattering contributions are ignored and only the 3D depth-dependent collimator resolution is considered.Keywords
This publication has 26 references indexed in Scilit:
- A scatter model for parallel and converging beam SPECT based on the Klein-Nishina formulaIEEE Transactions on Nuclear Science, 1994
- A practical method for incorporating scatter in a projector-backprojector for accurate scatter compensation in SPECTIEEE Transactions on Nuclear Science, 1993
- A fast projector-backprojector pair modeling the asymmetric, spatially varying scatter response function for scatter compensation in SPECT imagingIEEE Transactions on Nuclear Science, 1993
- Object shape dependent PSF model for SPECT imagingIEEE Transactions on Nuclear Science, 1993
- The GEM MAP algorithm with 3-D SPECT system responseIEEE Transactions on Medical Imaging, 1992
- Parameterization of the scatter response function in SPECT imaging using Monte Carlo simulationIEEE Transactions on Nuclear Science, 1990
- Improving the efficiency of emission tomography simulations using variance reduction techniquesIEEE Transactions on Nuclear Science, 1990
- Revised scatter fraction results for SPECTPhysics in Medicine & Biology, 1987
- Inverse Monte Carlo: A Unified Reconstruction Algorithm for SPECTIEEE Transactions on Nuclear Science, 1985
- Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigationPhysics in Medicine & Biology, 1984