Nanoliter Multiplex PCR Arrays on a SlipChip
- 6 May 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (11) , 4606-4612
- https://doi.org/10.1021/ac1007249
Abstract
The SlipChip platform was tested to perform high-throughput nanoliter multiplex PCR. The advantages of using the SlipChip platform for multiplex PCR include the ability to preload arrays of dry primers, instrument-free sample manipulation, small sample volume, and high-throughput capacity. The SlipChip was designed to preload one primer pair per reaction compartment and to screen up to 384 different primer pairs with less than 30 nanoliters of sample per reaction compartment. Both a 40-well and a 384-well design of the SlipChip were tested for multiplex PCR. In the geometries used here, the sample fluid was spontaneously compartmentalized into discrete volumes even before slipping of the two plates of the SlipChip, but slipping introduced additional capabilities that made devices more robust and versatile. The wells of this SlipChip were designed to overcome potential problems associated with thermal expansion. By using circular wells filled with oil and overlapping them with square wells filled with the aqueous PCR mixture, a droplet of aqueous PCR mixture was always surrounded by the lubricating fluid. In this design, during heating and thermal expansion, only oil was expelled from the compartment and leaking of the aqueous solution was prevented. Both 40-well and 384-well devices were found to be free from cross-contamination, and end point fluorescence detection provided reliable readout. Multiple samples could also be screened on the same SlipChip simultaneously. Multiplex PCR was validated on the 384-well SlipChip with 20 different primer pairs to identify 16 bacterial and fungal species commonly presented in blood infections. The SlipChip correctly identified five different bacterial or fungal species in separate experiments. In addition, the presence of the resistance gene mecA in methicillin resistant Staphylococcus aureus (MRSA) was identified. The SlipChip will be useful for applications involving PCR arrays and lays the foundation for new strategies for diagnostics, point-of-care devices, and immobilization-based arrays.Keywords
This publication has 82 references indexed in Scilit:
- Dead-End Filling of SlipChip Evaluated Theoretically and Experimentally as a Function of the Surface Chemistry and the Gap Size between the Plates for Lubricated and Dry SlipChipsLangmuir, 2010
- SlipChip for Immunoassays in Nanoliter VolumesAnalytical Chemistry, 2010
- Multiparameter Screening on SlipChip Used for Nanoliter Protein Crystallization Combining Free Interface Diffusion and Microbatch MethodsJournal of the American Chemical Society, 2009
- User-Loaded SlipChip for Equipment-Free Multiplexed Nanoliter-Scale ExperimentsJournal of the American Chemical Society, 2009
- Microdroplet-based PCR enrichment for large-scale targeted sequencingNature Biotechnology, 2009
- Microfluidic Confinement of Single Cells of Bacteria in Small Volumes Initiates High‐Density Behavior of Quorum Sensing and Growth and Reveals Its VariabilityAngewandte Chemie International Edition in English, 2009
- Laterally Mobile, Functionalized Self-Assembled Monolayers at the Fluorous−Aqueous Interface in a Plug-Based Microfluidic System: Characterization and Testing with Membrane Protein CrystallizationJournal of the American Chemical Society, 2009
- Plug‐Based Microfluidics with Defined Surface Chemistry to Miniaturize and Control Aggregation of Amyloidogenic PeptidesAngewandte Chemie International Edition in English, 2009
- Reactions in Droplets in Microfluidic ChannelsAngewandte Chemie International Edition in English, 2006
- Rapid detection of novelBRCA1 rearrangements in high-risk breast-ovarian cancer families using multiplex PCR of short fluorescent fragmentsHuman Mutation, 2002