Fellows' Forum in Dialysis edited by Mark A.Perazella: Blood Flow Surveillance of Hemodialysis Grafts: Insights from Two Case Reports
- 1 September 2002
- journal article
- case report
- Published by Wiley in Seminars in Dialysis
- Vol. 15 (5) , 370-374
- https://doi.org/10.1046/j.1525-139x.2002.00056.x
Abstract
It is widely recommended that all hemodialysis grafts undergo blood flow (Qa) surveillance, and that stenosis be corrected when accompanied by a low Qa or decrease in Qa (deltaQa). This recommendation has, however, become increasingly controversial. Studies have shown that although there is an association between Qa and thrombosis, the accuracy of Qa in predicting thrombosis within individual patients is poor. We describe two cases that demonstrate common causes of poor predictive accuracy. These cases also show that application of Qa surveillance algorithms is often complex and ambiguous. Most studies reporting that surveillance with intervention reduces thrombosis or prolongs graft life have used historical or sequential control groups, or have been retrospective. Accurate assessment of the benefit of graft surveillance must await studies that are fully prospective and randomized with concurrent control groups. Until such studies have demonstrated sufficient benefit, we do not recommend periodic Qa surveillance with intervention of all hemodialysis grafts.Keywords
This publication has 28 references indexed in Scilit:
- Association between blood pressure, ultrafiltration, and hemodialysis graft thrombosis: A multivariable logistic regression analysisAmerican Journal of Kidney Diseases, 2002
- Clinical performance characteristics of hemodialysis graft monitoringKidney International, 2001
- Predictors of arteriovenous graft patency after radiologic intervention in hemodialysis patientsAmerican Journal of Kidney Diseases, 2001
- Use of Vascular Access Blood Flow to Evaluate Vascular AccessAmerican Journal of Kidney Diseases, 2001
- In ReplyAmerican Journal of Kidney Diseases, 2001
- Intradialytic serial vascular access flow measurementsAmerican Journal of Kidney Diseases, 1999
- Does blood flow accurately predict thrombosis or failure of hemodialysis synthetic grafts? A meta-analysisAmerican Journal of Kidney Diseases, 1999
- Detection and treatment of dysfunctional hemodialysis access grafts: effect of a surveillance program on graft patency and the incidence of thrombosis.Radiology, 1996
- Theory and validation of access flow measurement by dilution technique during hemodialysisKidney International, 1995
- Duplex Scanning of Expanded Polytetrafluoroethylene Dialysis Shunts: Impact on Patient Management and Graft SurvivalVascular Surgery, 1993