An indoor system for the study of biological aerosols in open air conditions
- 1 December 1971
- journal article
- research article
- Published by Cambridge University Press (CUP) in Epidemiology and Infection
- Vol. 69 (4) , 607-617
- https://doi.org/10.1017/s0022172400021884
Abstract
SUMMARY: An indoor system designed for the study of survival of airborne micro-organisms in closed conditions has been successfully modified to allow the effect of open air to be measured. It was found that the unidentified open-air factors which are toxic for many species of microbes and rapidly lost when enclosed in conventional laboratory apparatus could be retained in the system by continuous ventilation at an adequate rate. The rate required allowed examination ofEscherichia coliin aerosols generated from small amounts of material because of the short periods of ventilation required for appreciable viable decay to occur.The validity of the system was tested by comparing the survival ofE. coliin true aerosols with its survival when the droplets were held on microthread. An investigation of the role of relative humidity in open-air toxicity was included.Keywords
This publication has 4 references indexed in Scilit: