Online 4-D CT Estimation for Patient-Specific Respiratory Motion Based on Real-Time Breathing Signals
- 1 January 2010
- book chapter
- Published by Springer Nature
- Vol. 13, 392-399
- https://doi.org/10.1007/978-3-642-15711-0_49
Abstract
In image-guided lung intervention, the electromagnetic (EM) tracked needle can be visualized in a pre-procedural CT by registering the EM tracking and the CT coordinate systems. However, there exist discrepancies between the static pre-procedural CT and the patient due to respiratory motion. This paper proposes an online 4-D CT estimation approach to patient-specific respiratory motion compensation. First, the motion patterns between 4-D CT data and respiratory signals such as fiducials from a number of patients are trained in a template space after image registration. These motion patterns can be used to estimate the patient-specific serial CTs from a static 3-D CT and the real-time respiratory signals of that patient, who do not generally take 4-D CTs. Specifically, the respiratory lung field motion vectors are projected onto the Kernel Principal Component Analysis (K-PCA) space, and a motion estimation model is constructed to estimate the lung field motion from the fiducial motion using the ridge regression method based on the least squares support vector machine (LS-SVM). The algorithm can be performed onsite prior to the intervention to generate the serial CT images according to the respiratory signals in advance, and the estimated CTs can be visualized in real-time during the intervention. In experiments, we evaluated the algorithm using leave-one-out strategy on 30 4-D CT data, and the results showed that the average errors of the lung field surfaces are 1.63mm.Keywords
This publication has 14 references indexed in Scilit:
- A Minimally Invasive Multimodality Image-Guided (MIMIG) Molecular Imaging System for Peripheral Lung Cancer Intervention and DiagnosisPublished by Springer Nature ,2010
- 4D‐CT motion estimation using deformable image registration and 5D respiratory motion modelingMedical Physics, 2008
- A patient‐specific respiratory model of anatomical motion for radiation treatment planningMedical Physics, 2007
- Fast cross-validation algorithms for least squares support vector machine and kernel ridge regressionPattern Recognition, 2007
- Inter-subject Modelling of Liver Deformation During Radiation TherapyPublished by Springer Nature ,2007
- 2714: Evaluating Lung Motion Variations in Repeated 4D CT Studies Using Inverse Consistent Image RegistrationInternational Journal of Radiation Oncology*Biology*Physics, 2006
- A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapyMedical Physics, 2006
- CLASSIC: Consistent Longitudinal Alignment and Segmentation for Serial Image ComputingPublished by Elsevier ,2005
- Iterative kernel principal component analysis for image modelingPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2005
- A Dynamic Model of Average Lung Deformation Using Capacity-Based Reparameterization and Shape Averaging of Lung MR ImagesPublished by Springer Nature ,2004