Application of microchip assay system for the measurement of C-reactive protein in human saliva
- 13 January 2005
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 5 (3) , 261-269
- https://doi.org/10.1039/b414194f
Abstract
In the last decade, saliva has been advocated as a non-invasive alternative to blood as a diagnostic fluid. However, use of saliva has been hindered by the inadequate sensitivity of current methods to detect the lower salivary concentrations of many constituents compared to serum. Furthermore, developments in the areas related to lab-on-a-chip systems for saliva-based point of care diagnostics are complicated by the high viscocity and heterogeneous properties associated with this diagnostic fluid. The biomarker C-reactive protein (CRP) is an acute phase reactant and a well-accepted indicator of inflammation. Numerous clinical studies have established elevated serum CRP as a strong, independent risk factor for the development of cardiovascular disease (CVD). CVD has also been associated with oral infections (i.e. periodontal diseases) and there is evidence that systemic CRP may be a link between the two. Clinical measurements of CRP in serum are currently performed with “high sensitivity” CRP (hsCRP) enzyme-linked immunosorbent assay (ELISA) tests that lack the sensitivity for the detection of this important biomarker in saliva. Because measurement of salivary CRP may represent a novel approach for diagnosing and monitoring chronic inflammatory disease, including CVD and periodontal diseases, the objective of this study was to apply an ultra-sensitive microchip assay system for the measurement of CRP in human saliva. Here, we describe this novel lab-on-a-chip system in its first application for the measurement of CRP in saliva and demonstrate its advantages over the traditional ELISA method. The increased sensitivity of the microchip system (10 pg ml−1 of CRP with 1000-fold dilution of saliva sample) is attributed to its inherent increased signal to noise ratio, resulting from the higher bead surface area available for antigen/antibody interactions and the high stringency washes associated with this approach. Finally, the microchip assay system was utilized in this study to provide direct experimental evidence that chronic periodontal disease may be associated with higher levels of salivary CRP.Keywords
This publication has 48 references indexed in Scilit:
- Saliva as a Diagnostic FluidDental Clinics of North America, 2010
- High-sensitivity C-reactive protein, inflammation, and cardiovascular risk: from concept to clinical practice to clinical benefitAmerican Heart Journal, 2004
- Micro Total Analysis Systems. Recent DevelopmentsAnalytical Chemistry, 2004
- A Multicomponent Sensing Ensemble in Solution: Differentiation between Structurally Similar AnalytesAngewandte Chemie International Edition in English, 2003
- Multishell Microspheres with Integrated Chromatographic and Detection Layers for Use in Array SensorsJournal of the American Chemical Society, 2003
- Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistryLab on a Chip, 2001
- Fully integrated PCR-capillary electrophoresis microsystem for DNA analysisLab on a Chip, 2001
- Stimulation of CRP secretion in HepG2 cells: Cooperative effect of dexamethasone and interleukin 6Inflammation Research, 1991
- The diagnostic uses of salivaJournal of Oral Pathology & Medicine, 1990
- Current Diagnostic Uses of SalivaJournal of Dental Research, 1987