Quantitative Airway Artefact Compensation at Regional Cerebral Blood Flow Measurements with Radioactive Gases

Abstract
An algorithm is described for detection and correction of airway contamination of clearance curves recorded extracranially during regional cerebral blood flow measurements with inert radioactive gases, mainly xenon-133.