Fixation of Cancellous Bone and Physeal Fractures in Dogs and Cats. A Comparison of the Use of Self-reinforced Biodegradable Devices to the Use of Metallic Devices and External Fixations
Open Access
- 1 September 1989
- journal article
- research article
- Published by Springer Nature in Acta Veterinaria Scandinavica
- Vol. 30 (3) , 259-265
- https://doi.org/10.1186/bf03548030
Abstract
The use of self-reinforced biodegradable devices made of polyglycolide in the cancellous bone and physeal fractures of dogs and cats was compared to the use of metallic devices and external fixations on similar fractures. The series consisted of 64 dogs and 22 cats divided into 6 comparable groups. The patients in the 2 groups fixed with biodegradable devices started to use their operated limbs earlier than in the other groups. The same 2 groups also healed clinically (showed no lameness) earlier than the other groups. Radiographically there was no statistical difference between the 6 groups. On the basis of this study it may be concluded that the fixation with self-reinforced biodegradable devices is as suitable for the fixation of cancellous bone and physeal fractures of dogs and cats as the fixation with metallic devices or external fixation. This biodegradable technique has additional benefits allowing the patients to feel less pain in their operated limbs and making secondary operations to remove the devices unnecessary.Keywords
This publication has 20 references indexed in Scilit:
- The use of a biodegradable implant in fracture fixation: a review of the literature and a report of two clinical casesJournal of Small Animal Practice, 1988
- The Effect of a Penetrating Biodegradable Implant on the Epiphyseal PlateJournal of Pediatric Orthopaedics, 1987
- Strength and strength retention vitro, of absorbable, self-reinforced polyglycolide (PGA) rods for fracture fixationBiomaterials, 1987
- Biodegradation of polyglycolic acid in bone tissue: An experimental study on rabbitsArchives of orthopaedic and trauma surgery, 1986
- BIODEGRADABLE IMPLANTS IN FRACTURE FIXATION: EARLY RESULTS OF TREATMENT OF FRACTURES OF THE ANKLEThe Lancet, 1985
- Effect of rigid plate fixation on structure and mineral content of cortical bone.1978
- The Effects of Rigidity of Internal Fixation Plates on Long Bone Remodeling:A Bio Mechanical and Quantitative Histological StudyActa Orthopaedica, 1976
- Bone Structure Changes in the Dog Under Rigid Internal FixationClinical Orthopaedics and Related Research, 1971
- Limb Fractures in the Dog and Cat—IV Fractures of the Fore LimbJournal of Small Animal Practice, 1966
- Limb Fractures in the Dog and Cat—III Post-operative Therapy and ManagementJournal of Small Animal Practice, 1966