The topographical effect of electrospun nanofibrous scaffolds on the in vivo and in vitro foreign body reaction
- 18 September 2009
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 93A (3) , 1151-1159
- https://doi.org/10.1002/jbm.a.32609
Abstract
Topographical cues play an important role in influencing cellular behavior and are considered as significant parameters to be controlled in tissue engineering applications. This work investigated the biocompatibility with regard to scaffold architecture and topographical effect of nanofibrous scaffolds on the in vivo and in vitro foreign body reaction. Random and aligned polycaprolactone (PCL) nanofibers were fabricated by electrospinning technique, with diameters of 313 ± 5 nm and 506 ± 24 nm, respectively. Primary monocytes isolated from five human donors were cultured on PCL nanofibers, PCL film, and RGD-coated glass in vitro and cell density and morphology was evaluated at time points of day 0 (2 h), day 3, day 7, and day 10. The in vivo study was carried out by implanting PCL nanofibers and film scaffolds subcutaneously in rats to test the biocompatibility and host response at time points of week 1, week 2, and week 4. The in vitro studies revealed that the initial monocyte adhesion on the aligned fiber scaffold was significantly less (p < 0.001) when compared to the random fiber scaffold. The in vivo study showed that the thicknesses of fibrous capsule on fibrous scaffolds were 7.55 ± 0.54 μm for aligned fibers and 4.13 ± 0.31 μm for random fibers, which were significantly thinner than that of film implants 37.7 ± 0.25 μm (p < 0.001). Additionally, cell infiltration was observed in aligned fibrous scaffolds both in vitro and in vivo, while on random fibers and films, distinct fibrous capsule boundaries were found on the surfaces. These results indicate that aligned electrospun nanofibers may serve as a promising scaffold for tissue engineering by minimizing host response, enhancing tissue-scaffold integration, and eliciting a thinner fibrous capsule. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res, 2010Keywords
This publication has 37 references indexed in Scilit:
- Topographical control of human macrophages by a regularly microstructured polyvinylidene fluoride surfaceBiomaterials, 2008
- Foreign body reaction to biomaterialsSeminars in Immunology, 2008
- Surface Chemistry Influences Implant BiocompatibilityCurrent Topics in Medicinal Chemistry, 2008
- In vivo evaluation of a dexamethasone/PLGA microsphere system designed to suppress the inflammatory tissue response to implantable medical devicesJournal of Biomedical Materials Research, 2002
- Reducing capsular thickness and enhancing angiogenesis around implant drug release systemsJournal of Controlled Release, 2001
- Biological Responses to MaterialsAnnual Review of Materials Research, 2001
- Assessment of a model for measuring drug diffusion through implant-generated fibrous capsule membranesBiomaterials, 1995
- Chemical and physical properties of collagen implants influence their fate in vivo as evaluated by light and confocal microscopyJournal of Biomedical Materials Research, 1994
- Intercapsular cataract surgery with lens epithelial cell removalJournal of Cataract & Refractive Surgery, 1991
- Preliminary in vivo biocompatibility studies on perfluorosulphonic acid polymer membranes for biosensor applicationsBiomaterials, 1991