A Methodological Study of the Enzymatic Determination of Glucose in Blood
- 1 January 1963
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 15 (4) , 415-428
- https://doi.org/10.3109/00365516309079764
Abstract
A methodological investigation of the glucose oxidase method for determination of glucose is described. The importance of eliminating substances reducing H2O2 generated from glucose and other substances causing unspecific oxidation of the chromogen is emphasized. On the basis of this study a method has been constructed which gives accurate glucose values in whole blood, plasma, and red blood cells.Keywords
This publication has 26 references indexed in Scilit:
- A galactose-oxidase method for the determination of galactose in blood plasmaClinica Chimica Acta; International Journal of Clinical Chemistry, 1962
- Enzymic determination of glucose and easily hydrolyzable glucose esters in bloodAnalytical Biochemistry, 1962
- Specific determination of blood glucose with o-toluidineClinica Chimica Acta; International Journal of Clinical Chemistry, 1962
- Automatic direct quantitation of radioactivity on paper chromatogramsBiochimica et Biophysica Acta, 1960
- Quantitative Determination of Blood Glucose Using Glucose Oxidase and PeroxidaseScandinavian Journal of Clinical and Laboratory Investigation, 1960
- On the Enzymatic Determination of Blood GlucoseScandinavian Journal of Clinical and Laboratory Investigation, 1960
- An improved glucose-oxidase method for determining blood C.S.F. and urine glucose levelsClinica Chimica Acta; International Journal of Clinical Chemistry, 1959
- Rapid Specific Method for Determination of Aldosaccharides in Body FluidsNature, 1959
- Rapid Colorimetric Micro-method for Estimating Glucose in Blood and C.S.F. Using Glucose OxidaseBMJ, 1957
- USE OF GLUCOSE OXIDASE, PEROXIDASE, AND O-DIANISIDINE IN DETERMINATION OF BLOOD AND URINARY GLUCOSEThe Lancet, 1957