Plain and Covered Stent-Grafts: In Vitro Evaluation of Characteristics at Three-dimensional MR Angiography
- 1 June 1999
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 211 (3) , 693-697
- https://doi.org/10.1148/radiology.211.3.r99jn23693
Abstract
To evaluate the characteristics of various plain and covered stents as regards demonstration of the contained lumen with simulated contrast material-enhanced fast three-dimensional (3D) magnetic resonance (MR) angiography. Six stents (Easy Wallstent, Cragg, Palmaz, Cragg EndoPro System 1, Corvita, Passager) were implanted in plastic tubes and integrated into a closed-tubing circuit driven by a pulsatile roller flow pump. The circulating water was spiked with gadopentetate dimeglumine. Three-dimensional MR angiograms were obtained with an echo time of 1.4 or 2.1 msec and with partial (0.5 signal acquired) or full (one signal acquired) k-space sampling. The size of the stent-associated artifact was determined relative to the tube diameter. The Easy Wallstent and Palmaz stent caused complete obliteration of the stent lumen with all sequences. The Cragg, Cragg EndoPro System 1, and Passager stents allowed good visualization of the stent lumen. The Corvita stent demonstrated major artifacts. The magnitude of the stent-associated artifact was related to the echo time (P < .01) but not to the type of k-space sampling (P = .35). The luminal patency of selected plain and covered stents can be assessed with contrast-enhanced 3D MR angiography.Keywords
This publication has 28 references indexed in Scilit:
- Aortic and lower-extremity arterial disease: evaluation with MR angiography versus conventional angiography.Radiology, 1998
- Evaluation of the aortoiliac and renal arteries: comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography.Radiology, 1997
- Breath-hold, contrast-enhanced, three-dimensional MR angiography.Radiology, 1996
- Aortic and iliac stenoses: follow-up results of stent placement after insufficient balloon angioplasty in 118 cases.Radiology, 1996
- Long iliac stenosis: initial clinical experience with the Cragg endoluminal graft.Radiology, 1995
- Nitinol intravascular stent: results of preclinical evaluation.Radiology, 1993
- Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriographyJournal of Magnetic Resonance Imaging, 1993
- Femoropopliteal stent placement: long-term results.Radiology, 1992
- Palmaz stent in atherosclerotic stenoses involving the ostia of the renal arteries: preliminary report of a multicenter study.Radiology, 1991
- Percutaneous iliac artery stent: angiographic long-term follow-up.Radiology, 1991