Cardiogenic motion of right lung parenchyma in anesthetized intact dogs
- 1 February 1985
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 58 (2) , 384-391
- https://doi.org/10.1152/jappl.1985.58.2.384
Abstract
Cardiogenic motion of the right lung parenchyma (CGLM) was measured in six morphine-pentobarbital-anesthetized dogs (11–16 kg) under conditions of varying paced and spontaneous sinus heart rates. Motion of 1-mm-diameter percutaneously implanted radiopaque lung parenchymal markers were measured using a computer-based biplane video-roentgenographic assembly. Correlation of the amplitudes and phases of marker motions to the R wave of the electrocardiogram (ECG) were determined utilizing a modified fast Fourier transform algorithm. Of initial importance was the observation that CGLM was significantly greater than the variability of repeated measurements. The total amplitudes of motion of the markers (where AT = square root A2X + A2Y + A2Z and AX, AY, AZ are the amplitudes of marker motion along the orthogonal X, Y, and Z body axes) in the right apical, cardiac, and diaphragmatic lobes were 0.025 +/- 0.005 (SE), 0.046 +/- 0.005, and 0.023 +/- 0.025 cm, respectively, (P less than 0.01, cardiac lobe vs. others). The total amplitude of motion observed in the cardiac lobe was equivalent to earlier observations of total amplitude (0.045 +/- 0.004 cm) of marker motion in response to high frequency airway oscillation at a pump stroke volume of 22–26 ml. An analysis of the higher harmonics of marker oscillation suggested that the second harmonic of CGLM is also larger than the variability of our measurements.This publication has 9 references indexed in Scilit:
- Estimation of regional pleural surface expansile forces in intact dogsJournal of Applied Physiology, 1983
- Intrapulmonary gas transport and perfusion during high-frequency oscillationJournal of Applied Physiology, 1981
- Gas mixing by cardiogenic oscillations: a theoretical quantitative analysisJournal of Applied Physiology, 1981
- CO2 ELIMINATION BY HIGH-FREQUENCY VENTILATION (4 TO 10 HZ) IN NORMAL SUBJECTSPublished by Elsevier ,1981
- Ventilation by high-frequency oscillationJournal of Applied Physiology, 1980
- Regional lung expansion at total lung capacity in intact vs. excised canine lungsJournal of Applied Physiology, 1978
- Influence of pericardial fluid on cardiogenic gas mixing in the lungJournal of Applied Physiology, 1977
- Biplane videoangiography.Journal of Applied Physiology, 1968
- Pulsatile gas flow in bronchi caused by the heart beatJournal of Applied Physiology, 1961