Release of endogenous vasopressors during and after cardiopulmonary resuscitation.
Open Access
- 1 February 1996
- Vol. 75 (2) , 145-150
- https://doi.org/10.1136/hrt.75.2.145
Abstract
OBJECTIVE: To assess whether plasma endothelin, adrenaline, noradrenaline, arginine vasopressin, adrenocorticotropin, and cortisol concentrations were higher during cardiopulmonary resuscitation in patients in whom resuscitation was successful than in those in whom it failed, and to measure the concentrations of these hormones in the immediate post-resuscitation phase. DESIGN: Prospective, descriptive study. SETTING: Emergency medical service at a university hospital. PATIENTS: 60 patients with cardiac arrest out of hospital. INTERVENTIONS: Blood samples were drawn and blood pressure and heart rate were measured during cardiopulmonary resuscitation, before and after the first dose of adrenaline was given and at 5, 15, 30, and 60 minutes after the restoration of spontaneous circulation. Plasma hormone concentrations were measured by radio-immunoassays. RESULTS: 24 of the 60 patients were successfully resuscitated and admitted to hospital: 36 were not. During cardiopulmonary resuscitation before adrenaline was given, the plasma concentration of endothelin (mean (SEM)) in resuscitated and in not resuscitated patients was 4.3 (0.9) pg/ml and 5.5 (0.4) pg/ml respectively (NS), adrenaline was 14.1 (2.0) ng/ml and 25.3 (3.6) ng/ml (P < 0.01), noradrenaline was 5.0 (0.9 ng/ml) and 8.4 (1.1 ng/ml) (P < 0.05), arginine vasopressin was 193 (28) pg/ml and 70 (9) pg/ml (P < 0.001), adrenocorticotropin was 128 (34) pg/ml and 57 (6) pg/ml (P < 0.05), and cortisol was 18 (3) microgram/dl and 15 (2) microgram/dl (NS). During cardiopulmonary resuscitation after adrenaline was given endothelin in resuscitated and in not resuscitated patients was 4.0 (1.0) pg/ml and 5.3 (0.5) pg/ml (NS), adrenaline was 145 (16) ng/ml and 201 (21) ng/ml (P < 0.05), noradrenaline was 3.9 (0.9) ng/ml and 8.3 (1.1) ng/ml (P < 0.01), arginine vasopressin was 177 (27) pg/ml and 58 (9) pg/ml (P < 0.001), adrenocorticotropin was 234 (92) pg/ml and 85 (9) pg/ml (P < 0.001), and cortisol was 17 (2) microgram/dl and 13 (2) microgram/dl (NS). CONCLUSIONS: Despite a tremendous adrenosympathetic response, the lower arginine vasopressin and adrenocorticotropin concentrations during cardiopulmonary resuscitation in patients in whom resuscitation failed may influence vital organ perfusion and hence the success of resuscitation. Plasma concentrations of arginine vasopressin and adrenocorticotropin may have a more important effect on outcome than previously thought.Keywords
This publication has 18 references indexed in Scilit:
- Endothelins in the control of cardiovascular and renal functionThe Lancet, 1993
- A characterization of hypothalamic-pituitary-adrenal axis function during and after human cardiac arrestCritical Care Medicine, 1993
- Effect of Vasopressin on Hemodynamic Variables, Organ Blood Flow, and Acid-Base Status in a Pig Model of Cardiopulmonary ResuscitationAnesthesia & Analgesia, 1993
- Endothelins—from receptors to medicineTrends in Pharmacological Sciences, 1993
- A Comparison of Standard-Dose and High-Dose Epinephrine in Cardiac Arrest outside the HospitalNew England Journal of Medicine, 1992
- Hemodynamic and metabolic effects of epinephrine during cardiopulmonary resuscitation in a pig modelCritical Care Medicine, 1992
- Plasma catecholamine concentrations after successful resuscitation in patientsCritical Care Medicine, 1992
- Plasma endothelin during upright tilt: relevance for orthostatic hypotension?The Lancet, 1991
- Relative roles of cardiac and arterial baroreceptors in vasopressin regulation during hemorrhage in conscious dogs.Circulation Research, 1991
- Influence of Epinephrine on Systemic, Myocardial, and Cerebral Acid-Base Status during Cardiopulmonary ResuscitationAnesthesiology, 1991