In Vivo Ultrasonic Parametric Imaging of Carotid Atherosclerotic Plaque by Videodensitometric Technique
- 1 August 1995
- journal article
- Published by SAGE Publications in Angiology
- Vol. 46 (8) , 663-672
- https://doi.org/10.1177/000331979504600804
Abstract
Extensive experimental and clinical data show that the ultrasonic image conveys infor mation on the biochemical composition of the atherosclerotic plaque, ie, the relative content of lipids (hypoechoic), fibrous tissue (hyperechoic), and calcific deposits (very echogenic with shadowing). A more dishomogeneous echo structure of the plaque is also more often associated with clinically complicated carotid plaques. To date, however, the assessment of plaque density and homogeneity by transcutaneous B-mode imaging remains subjective and qualitative. The aim of this study was to assess whether plaque echodensity and homogeneity might be established on a more objective and quantitative basis by description of the spatial distribution of echo amplitude (referred to as tissue texture) applied to digitized images, obtained with commercially available B-mode transcutaneous imaging systems. A total of 47 B-mode images derived from echotomographic studies in 10 patients were digitized off line. For each region of interest, a set of first-order (mean gray level, standard deviation, skewness, kurtosis: mathematical descriptors of the shape of the frequency distribution of gray-level histogram) and of second-order (entropy, angular moment: mathematical descriptors of the spatial distribution of gray levels within the region of interest) textural parameters were evaluated. The visual, concordant reading by two independent, experienced observers assigned the plaques on the basis of qualita tively assessed echodensity to three groups: "soft" (n = 18), "fibrotic" (n = 20), "calcific" (n = 9). Regarding spatial gray-level distribution, 46 plaques would be separated into "homogeneous" (n = 17) and "dishomogeneous" (n = 29). On digitized images, the normalized mean gray level was the most effective first-order textural parameter for distinguishing soft (24.2 ± 12.4 arbitrary units in a zero to 255 scale) from fibrotic (64.5 ±16.4) and calcific plaques (125.3 ±24.5), P<0.01 for all intergroup differences. "Homogeneous" plaques were separated from "heterogeneous" ones on the basis of entropy (5 ±1 vs 7.9 ±9.7; P<0.01), whereas the values of angular second moment overlapped (1.542E-3 + 1.334E-3 vs 5.181E-4 ±2.5615E-4, P = ns). In conclusion, quantitative texture analysis of ultrasonic images derived from tran scutaneous, high-resolution, commercially available B-scan systems is feasible in man and provides a quantitative operator-independent assessment of plaque echodensity and homogeneity.Keywords
This publication has 15 references indexed in Scilit:
- Increased echodensity of transiently asynergic myocardium in humans: A novel echocardiographic sign of myocardial ischemiaJournal of the American College of Cardiology, 1993
- Intravascular ultrasound. Looking below the surface of vascular disease.Circulation, 1990
- Noninvasive assessment of myocardial composition and function in the hypertrophied heart.Circulation, 1989
- Quantitative texture analysis in two-dimensional echocardiography: Application to the diagnosis of myocardial amyloidosisJournal of the American College of Cardiology, 1989
- Time domain echo pattern evaluations from normal and atherosclerotic arterial walls: a study in vitro.Circulation, 1988
- The use of frequency histograms of ultrasonic backscatter amplitudes for detection of atherosclerosis in vitro.Circulation, 1986
- Evaluation of frequency dependence of backscatter coefficient in normal and atherosclerotic aortic wallsUltrasound in Medicine & Biology, 1986
- Angle dependence of ultrasonic backscatter in arterial tissues: a study in vitro.Circulation, 1985
- Ultrasonic characterization of myocardiumProgress in Cardiovascular Diseases, 1985
- Fibrosis, lipids, and calcium in human atherosclerotic plaque. In vitro differentiation from normal aortic walls by ultrasonic attenuation.Circulation Research, 1985