Amniotic Fluid Pressure in Both Cavities of Twin-to-Twin Transfusion Syndrome: A Vote against Septostomy
- 9 March 2000
- journal article
- Published by S. Karger AG in Fetal Diagnosis and Therapy
- Vol. 15 (2) , 79-82
- https://doi.org/10.1159/000020980
Abstract
Objective: To report our results of the measurement of the amniotic fluid pressure in twin-to-twin transfusion syndrome before and after amniodrainage and the separate measurement in the cavity of the stuck twin and the recipient, respectively, in 2 cases. Method: Six patients with severe TTS underwent therapeutic amniodrainage. Amniotic fluid pressure was obtained before and after reduction of the fluid volume. In 2 of these cases we were able to calculate the pressure separately in both amniotic cavities, the donors (stuck twin) and the recipients. Results: In all cases of TTS, amniotic pressure was high before and reduced after amniodrainage. The pressure was equal in the donors and in the recipients cavity. Conclusion: Amniotic pressure seems to be high in TTS, but equal in both cavities. Therefore, amniotic septostomy is probably of low value, especially if a high-risk monoamniotic situation is artificially created.Keywords