Serodiagnosis of human plague by a combination of immunomagnetic separation and flow cytometry
- 19 May 2003
- journal article
- research article
- Published by Wiley in Cytometry Part A
- Vol. 53A (2) , 88-96
- https://doi.org/10.1002/cyto.a.10040
Abstract
Background: Plague is a severe, highly communicable bacterial disease caused by Yersinia pestis. It is still endemic in more than 20 countries worldwide. Although known as a devastating disease for centuries, laboratory confirmation of clinical suspected cases is still problematic. No standardized and internationally approved test system is commercially available. The aim of this study was the introduction and evaluation of a combination of immunomagnetic separation and flow cytometry for the serodiagnosis of human plague.Methods: Paramagnetic polystyrene beads were coated with purified F1 capsular antigen (F1 CA) and reacted with sera from plague patients, from 26 laboratory personnel vaccinated against plague and from 102 healthy blood donors (HBD). After incubation with fluorescein isothiocyanate–conjugated anti‐human rabbit IgG, particle‐associated fluorescence was detected by flow cytometry.Results: Anti‐F1 CA antibodies could be demonstrated in all patients with bacteriologically confirmed plague and in 22 sera (84.6%) from vaccinees. Only one serum in the HBD group showed a weakly positive reaction. The total assay time was less than 2 h.Conclusions: Compared with a recently published combination of an anti‐F1 CA enzyme‐linked immunosorbent assay (ELISA) and immunoblot, the new assay showed the same sensitivity as the ELISA and almost the same specificity (99.0 versus 100%) as the immunoblot. Allowing a rapid, reliable, and quantitative analysis, immunomagnetic separation combined with flow cytometry might replace both conventional immunoassays. Cytometry Part A 53A:88–96, 2003.Keywords
This publication has 24 references indexed in Scilit:
- A Combination of Different Polymerase Chain Reaction (PCR) Assays for the Presumptive Identification of Yersinia pestisJournal of Veterinary Medicine, Series B, 2000
- Serodiagnosis of human plague by an anti-F1 capsular antigen specific IgG/IgM ELISA and immunoblotEpidemiology and Infection, 2000
- Rapid detection of Escherichia coli O157:H7 using immuno-magnetic flow cytometry in ground beef, apple juice, and milkInternational Journal of Food Microbiology, 1998
- F1 antigenaemia in bubonic plague patients, a marker of gravity and efficacy of therapyTransactions of the Royal Society of Tropical Medicine and Hygiene, 1998
- Transmission of HIV-1 in Infants Born to Seropositive MothersJAIDS Journal of Acquired Immune Deficiency Syndromes, 1997
- Dual analyte assay based on particle types of different size measured by flow cytometryJournal of Immunological Methods, 1995
- Magnetic separation techniques in diagnostic microbiologyClinical Microbiology Reviews, 1994
- Chapter 33 Flow Microsphere Immunoassay for the Quantitative and Simultaneous Detection of Multiple Soluble AnalytesPublished by Elsevier ,1994
- Immunometric assay by flow cytometry using mixtures of two particle types of different affinityJournal of Immunological Methods, 1990
- Development of a microsphere-based fluorescent immunoassay and its comparison to an enzyme immunoassay for the detection of antibodies to three antigen preparations from Candida albicansJournal of Immunological Methods, 1989