Femtosecond laser versus mechanical keratome flaps in wavefront-guided laser in situ keratomileusis
Top Cited Papers
- 1 January 2005
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (1) , 120-126
- https://doi.org/10.1016/j.jcrs.2004.09.046
Abstract
To compare the outcomes of wavefront-guided laser in situ keratomileusis (LASIK) performed using the IntraLase femtosecond laser with the outcomes using the Hansatome mechanical microkeratome. Private clinic, Overland Park, Kansas, USA. In a prospective contralateral-eye study performed under institutional review board supervision, 51 consecutive patients (102 eyes) had bilateral wavefront-guided LASIK for myopia using the Alcon LADARVision laser. One eye of each patient was randomized to have the flap created with the IntraLase femtosecond laser and the other flap using a standard compression head Hansatome microkeratome. All other treatment parameters were the same. The IntraLase group had significantly better mean uncorrected visual acuity (UCVA) at all intervals from 1 day to 3 months postoperatively. The mean spheroequivalent at 3 months was more myopic with the Hansatome (-0.34 diopter [D] +/- 0.28 [SD]) than with the IntraLase (-0.19 +/- 0.24 D) (P<.01). The mean residual astigmatism at 3 months was also significantly higher in the Hansatome group than in the IntraLase group (0.32 +/- 0.25 D and 0.17 +/- 0.20 D, respectively) (P<.01). The differences in UCVA persisted after spheroequivalent outcomes were controlled for but equilibrated when the analysis was modified to control for manifest postoperative astigmatism. Aberrometry showed significantly higher astigmatism and trefoil in the Hansatome group. Recovery of corneal sensation and epithelial integrity was similar between groups. The statistically better UCVA and manifest refractive outcomes after LASIK with the IntraLase femtosecond laser may be the result of differences in postoperative astigmatism and trefoil. These findings are consistent with previous findings of better astigmatic outcomes with the IntraLase laser and may have clinical significance for wavefront-guided treatments.Keywords
This publication has 10 references indexed in Scilit:
- Recent advances in representation of monochromatic aberrations of human eyesClinical and Experimental Optometry, 2004
- Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2004
- Separate effects of the microkeratome incision and laser ablation on the eye’s wave aberrationAmerican Journal of Ophthalmology, 2003
- Induced optical aberrations following formation of a laser in situ keratomileusis flapJournal of Cataract & Refractive Surgery, 2002
- Are All Aberrations Equal?Journal of Refractive Surgery, 2002
- Wavefront Data Reporting and TerminologyJournal of Refractive Surgery, 2001
- Wavefront Customized Ablations With the WASCA Asclepion WorkstationJournal of Refractive Surgery, 2001
- Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatismJournal of Cataract & Refractive Surgery, 2001
- Proper Method for Calculating Average Visual AcuityJournal of Refractive Surgery, 1997