Flow injection–fluorimetric method for the determination of ranitidine in pharmaceutical preparations using o-phthalaldehyde
- 1 January 1996
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 121 (8) , 1043-1046
- https://doi.org/10.1039/an9962101043
Abstract
A flow injection–fluorimetric procedure for the determination of ranitidine is proposed. The assay is based on the reaction of the drug with sodium hypochlorite, to produce a primary amine, which reacts with o-phthalaldehyde and 2-mercaptoethanol to form highly fluorescent derivatives. The calibration graph, based on peak area, is linear in the range 20–500 ng ml–1 of ranitidine with an accuracy of 3.4%. The corresponding detection limit is 13 ng ml–1(3.7 pmol). The method was applied to the determination of ranitidine in pharmaceuticals. The recovery was quantitative and no interferences from excipients were observed.Keywords
This publication has 30 references indexed in Scilit:
- Determination of ranitidine in rat plasma and brain by high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1987
- High-performance liquid chromatographic determination of ranitidine in whole blood and plasma by using a short polymeric columnJournal of Chromatography B: Biomedical Sciences and Applications, 1987
- Rapid analysis of ranitidine in biological fluids and determination of its erythrocyte partitioningJournal of Chromatography B: Biomedical Sciences and Applications, 1985
- Simultaneous Analysis of Cimetidine and Ranitidine in Human Plasma by HPLCJournal of Liquid Chromatography, 1984
- High-performance liquid chromatographic methods for the determination of ranitidine and its metabolites in biological fluidsChromatographia, 1984
- High-performance liquid chromatography of ranitidine in pharmaceuticalsJournal of Pharmaceutical and Biomedical Analysis, 1984
- Determination of ranitidine and its metabolites in human urine by reversed-phase ion-pair high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1981
- High-pressure liquid chromatographic determination of ranitidine, a new H2-receptor antagonist, in plasma and urineJournal of Pharmaceutical Sciences, 1980
- Analysis of Ranitidine in Serum by High Performance Liquid ChromatographyTherapeutic Drug Monitoring, 1980
- A High Performance Liquid Chromatography Method for the Determination of Ranitidine in PlasmaJournal of Liquid Chromatography, 1979