Selective Permeation of Hydrogen Peroxide through Polyelectrolyte Multilayer Films and Its Use for Amperometric Biosensors
- 28 September 2001
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (21) , 5310-5315
- https://doi.org/10.1021/ac010605t
Abstract
A platinum electrode was coated with polyelectrolyte multilayer (PEM) films to prepare an amperometric hydrogen peroxide sensor which can be used in the presence of possible interferences such as ascorbic acid, uric acid, and acetaminophen. The PEM films were prepared on the surface of a Pt disk electrode by an alternate deposition of polycation and polyanion from the aqueous solutions through electrostatic force of attraction. The Pt electrodes coated with a poly(allylamine)/poly(vinyl sulfate) or poly(allylamine)/poly(styrenesulfonate) film were used successfully for detecting H2O2 selectively in the presence of the possible interfering agents. It was suggested that H2O2 can diffuse into the PEM film smoothly while the ascorbic acid, uric acid, and acetaminophen cannot penetrate the film by a size exclusion mechanism. On the other hand, the electrodes coated with PEM films containing poly(ethyleneimine) or poly(diallyldimethylammonium chloride) were not useful for the selective determination of H2O2. The results were rationalized based on the different permeability of the films due to the different molecular density or packing in the PEM films. The PEM film-coated electrode was useful for constructing glucose biosensors by coupling with glucose oxidase.Keywords
This publication has 52 references indexed in Scilit:
- Layered Polyelectrolyte Films on Au Electrodes: Characterization of Electron-Transfer Features at the Charged Polymer Interface and Application for Selective Redox ReactionsLangmuir, 2001
- Fabrication of multilayer films containing horseradish peroxidase and polycation-bearing Os complex by means of electrostatic layer-by-layer adsorption and its application as a hydrogen peroxide sensorAnalytica Chimica Acta, 2000
- Fabrication of multilayer films containing horseradish peroxidase based on electrostatic interaction and their application as a hydrogen peroxide sensorElectrochimica Acta, 1999
- A careful examination of the adsorption step in the alternate layer-by-layer assembly of linear polyanion and polycationColloids and Surfaces A: Physicochemical and Engineering Aspects, 1999
- Preparation of active avidin films by a layer-by-layer deposition of poly(vinyl sulfate) and avidin on a solid surfaceJournal of the Chemical Society, Perkin Transactions 2, 1999
- Detailed Structure of Molecularly Thin Polyelectrolyte Multilayer Films on Solid Substrates as Revealed by Neutron ReflectometryMacromolecules, 1998
- Glucose oxidase/polyion complex-bilayer membrane for elimination of electroactive interferents in amperometric glucose sensorAnalytica Chimica Acta, 1998
- Amperometric glucose sensors based on ferrocene-containing B-polyethylenimine and immobilized glucose oxidaseAnalytica Chimica Acta, 1997
- Layer-by-layer deposition of avidin and polymers on a solid surface to prepare thin films: significant effects of molecular geometry of the polymers on the deposition behaviourJournal of the Chemical Society, Perkin Transactions 2, 1997
- Amperometric l-lactate-sensing electrode based on a polyion complex layer containing lactate oxidase. Application to serum and milk samplesAnalytica Chimica Acta, 1995