Purification of Contaminated Peptides and Proteins on Synthetic Membrane Surfaces for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
- 8 January 1998
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 70 (4) , 750-756
- https://doi.org/10.1021/ac970969e
Abstract
Effective MALDI-TOF MS of salt-, detergent-, and glycerol-contaminated peptide and protein samples is accomplished by loading samples onto synthetic membranes, washing away contaminants, adding matrix, and desorbing samples directly from the membrane surface. The method easily removes contaminants which prevent effective MALDI of peptides and proteins from stainless steel surfaces, obviating the need for laborious further purification and associated sample losses. Polyethylene, polypropylene, C8, and C18 surfaces all proved effective at removing contaminants. Scanning electron microscope images of sample surfaces reveal that significantly smaller matrix crystals form on polyethylene and polypropylene surfaces than on stainless steel, C8, or C18 surfaces. Desorption from polyethylene and polypropylene surfaces generates consistently reproducible spectra with better mass resolution than observed for samples desorbed from stainless steel. Improved resolution, combined with reduced intensity of product ion spectra, indicate that peptide and protein molecular ions have less internal energy when desorbed from polyethylene and polypropylene surfaces than from stainless steel. MALDI of contaminated samples can be accomplished by straightforward, on-probe purification, resulting in higher resolution spectra than observed in samples desorbed from stainless steel.Keywords
This publication has 12 references indexed in Scilit:
- Matrix-assisted ultraviolet laser desorption of non-volatile compoundsPublished by Elsevier ,2001
- Surfaces for interfacing protein gel electrophoresis directly with mass spectrometryMass Spectrometry Reviews, 1995
- Sequencing electroblotted proteins by tandem mass spectrometryRapid Communications in Mass Spectrometry, 1995
- Poly(vinylidene difluoride) membranes as the interface between laser desorption mass spectrometry, gel electrophoresis, and in situ proteolysisAnalytical Chemistry, 1994
- Matrix-assisted laser desorption ionization mass spectrometry of proteins electroblotted after polyacrylamide gel electrophoresisAnalytical Chemistry, 1994
- Resolution of a protein sequence ambiguity by X-ray crystallographic and mass spectrometric methodsJournal of Applied Crystallography, 1992
- A matrix‐assisted laser desorption time‐of‐flight mass spectrometer based on a 600ps, 1.2 mJ nitrogen laserRapid Communications in Mass Spectrometry, 1991
- A study of the fragmentation of singly and multiply charged ions produced by 252Cf fission fragment bombardment of polypeptides bound to nitrocelluloseInternational Journal of Mass Spectrometry and Ion Processes, 1987
- Glutathione as a matrix for plasma desorption mass spectrometry of large peptidesAnalytical Chemistry, 1986
- Plasma desorption mass spectrometry of peptides and proteins adsorbed on nitrocelluloseAnalytical Chemistry, 1986