A readout magnet for prepolarized MRI
- 1 October 1996
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 36 (4) , 527-536
- https://doi.org/10.1002/mrm.1910360405
Abstract
Conventional MRI systems rely on large magnets to generate a field that is both strong and extremely uniform. This field is usually produced by a heavy permanent magnet or a cryogenically cooled superconductor. An alternative approach, called prepolarized MRI (PMRI), employs two separate fields produced by two different magnets. A strong and inhomogeneous magnetic field is used to polarize the sample. After polarization, a weak magnetic field is used for readout. These fields can be produced by two separate resistive electromagnets that cost significantly less than a single permanent or superconducting magnet. At Stanford, the authors are constructing a PMRI prototype scanner suitable for imaging human extremities roughly 20 cm in diameter. With this system the authors hope to demonstrate comparable image quality to MRI with reduced system cost. The authors' initial work on low‐frequency reception indicates that it will be possible to obtain comparable image signal‐to‐noise ratio to an MRI scanner operating at the same polarizing field strength. To reduce the capital cost of the system, the authors use resistive electromagnets. Here the authors discuss the full development of the readout magnet including important design considerations, shimming, and field plots. These encouraging results are an important step toward evaluating the cost effectiveness of PMRI.Keywords
This publication has 18 references indexed in Scilit:
- NMR imaging in the earth's magnetic fieldMagnetic Resonance in Medicine, 1990
- Environmental optimization and shielding for nmr experiments and imaging in the earth's magnetic fieldMagnetic Resonance in Medicine, 1990
- Stability and noise performance of constant transimpedance amplifier with inductive sourceIEEE Transactions on Circuits and Systems, 1989
- Proton-electron double magnetic resonance imaging of free radical solutionsJournal of Magnetic Resonance (1969), 1988
- Low Field (0.02 T) Nuclear Magnetic Resonance Imaging of the BrainJournal of Computer Assisted Tomography, 1985
- Overcoupling NMR probes to improve transient responseJournal of Magnetic Resonance (1969), 1983
- A whole-body NMR imaging machineJournal of Physics E: Scientific Instruments, 1980
- The sensitivity of the zeugmatographic experiment involving human samplesJournal of Magnetic Resonance (1969), 1979
- Thick Cylindrical Coil Systems for Strong Magnetic Fields with Field or Gradient Homogeneities of the 6th to 20th OrderJournal of Applied Physics, 1967
- Combinations of Circular Currents for Producing Uniform Magnetic FieldsReview of Scientific Instruments, 1936