Abstract
Although we and others have employed a thresholding strategy to extract “peak” values from positron emission tomographic (PET) regions of interest (ROIs), the effects of peak picking on fitted fluorodeoxyglucose rate constants, regional metabolic rate for glucose (rCMRglc) profiles, patterns of regional metabolic covariation, and PET-neurobehavioral correlations have not been systematically investigated. Our results suggest that under some commonly encountered imaging conditions percent thresholding may increase sensitivity to regional activation; however, the effect of thresholding is determined by a number of factors, including the relative magnitude of regional activation, ROI size, and the specific threshold selected. The difference-annulus concept is proposed as a means to study the effects of different region drawing and thresholding strategies, and to determine if a given ROI contains one and only one source of covarying metabolic activity.Keywords
This publication has 9 references indexed in Scilit:
- Absolute Quantitation in Neurological PET: Do We Need it?Journal of Cerebral Blood Flow & Metabolism, 1991
- The metabolic anatomy of paraneoplastic cerebellar degenerationAnnals of Neurology, 1988
- The metabolic pathology of the AIDS dementia complexAnnals of Neurology, 1987
- Scaled Subprofile Model: A Statistical Approach to the Analysis of Functional Patterns in Positron Emission Tomographic DataJournal of Cerebral Blood Flow & Metabolism, 1987
- The synthesis of high radiochemical purity of 2‐[18F]‐fluoro‐2‐deoxy‐D‐glucose without the use of preparative hplcJournal of Labelled Compounds and Radiopharmaceuticals, 1987
- V. Anatomical ConsiderationsJournal of Cerebral Blood Flow & Metabolism, 1987
- Effect of Vascular Activity in the Determination of Rate Constants for the Uptake of 18F-Labeled 2-Fluoro-2-Deoxy-D-Glucose: Error Analysis and Normal Values in Older SubjectsJournal of Cerebral Blood Flow & Metabolism, 1986
- Evaluation of the Performance Characteristics of the PC 4600 Positron Emission TomographJournal of Computer Assisted Tomography, 1984
- Tomographic measurement of local cerebral glucose metabolic rate in humans with (F‐18)2‐fluoro‐2‐deoxy‐D‐glucose: Validation of methodAnnals of Neurology, 1979